Back to Search Start Over

Performance Analysis of the Water Treatment Reverse Osmosis Plant.

Authors :
Agrawal, Amrita
Garg, Deepika
Kumar, Arun
Kumar, Rakesh
Source :
Reliability: Theory & Applications. Sep2021, Vol. 16 Issue 3, p16-25. 10p.
Publication Year :
2021

Abstract

In this research paper, profit analysis of a Water Treatment Reverse Osmosis (RO) Plant is carried out by using the Regenerative Point Graphical Technique (RPGT) under specific conditions for system parameters. The paper analyzes the behavior of a water treatment RO plant consisting of subunits namely Multimedia filter (MMF), Cartridge filter (CF), High-pressure pump (HPP), RO System (ROS). The system is in a working state when all subunits are in good condition. A repair facility is accessible for all subunits. Availability of the plant, Busy Period of the Server (BPS) and Expected number of inspection by the repairman (ENIR) is calculated by using the RPGT technique. Finally, numerical analysis is carried out for calculating the performance measures and their comparisons. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19322321
Volume :
16
Issue :
3
Database :
Academic Search Index
Journal :
Reliability: Theory & Applications
Publication Type :
Academic Journal
Accession number :