Back to Search Start Over

A new method to identify synchronous generator and turbine‐governor parameters of a gas unit using a closed‐loop model.

Authors :
Zaker, Behrooz
Khalili, Ramtin
Rabieyan, Hadi
Karrari, Mehdi
Source :
International Transactions on Electrical Energy Systems. Nov2021, Vol. 31 Issue 11, p1-21. 21p.
Publication Year :
2021

Abstract

Summary: In this paper, an efficient three‐stage algorithm for identifying the turbine‐governor (TG) and synchronous generator (SG) parameters is proposed. Instead of considering approximate models, precise models of the TG and SG are used. In the proposed approach, d‐q axes parameters of SG, mechanical parameters of SG, and TG model parameters are estimated. For the TG model, all the main control loops are carefully modeled with respect to the real‐world system. Moreover, the robustness of the governor is enhanced by employing an anti‐windup configuration for the load‐speed controller. The well‐known seventh‐order SG model is also used. The accuracy of the model and effectiveness of the parameter identification procedure is verified by experimental data. The results show satisfactory numbers for the selected performance index in various operating points when different controllers are in effect. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20507038
Volume :
31
Issue :
11
Database :
Academic Search Index
Journal :
International Transactions on Electrical Energy Systems
Publication Type :
Academic Journal
Accession number :
153384398
Full Text :
https://doi.org/10.1002/2050-7038.13110