Back to Search Start Over

Winding Condition Monitoring for Inverter-Fed PMSM Using High-Frequency Current Injection.

Authors :
Xu, Zheng
Zhang, Jianzhong
Zhang, Yaqian
Zhao, Jin
Source :
IEEE Transactions on Industry Applications. Nov/Dec2021, Vol. 57 Issue 6, p5818-5828. 11p.
Publication Year :
2021

Abstract

This article proposes a winding condition monitoring scheme for inverter-fed permanent magnet synchronous machine (PMSM) based on high frequency (HF) current injection. By setting specific current references for the HF positive and negative sequence current regulators, HF current can be injected into different phase winding pairs, and then the HF line voltage deviations are extracted for winding condition monitoring. The amplitude of the extracted HF line voltage deviation is defined as the condition indicator to evaluate the condition of phase winding. In the proposed method, the conditions of all phase windings can be separately monitored, where not only inter-turn short-circuit fault (ISF) in one phase but also ISFs in multiple phases can be accurately identified. Simulations and experiments have been carried out to validate the proposed method. It shows that the proposed method has high sensitivity to ISF and negligible sensitivity to the operation conditions of the PMSM. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00939994
Volume :
57
Issue :
6
Database :
Academic Search Index
Journal :
IEEE Transactions on Industry Applications
Publication Type :
Academic Journal
Accession number :
153854403
Full Text :
https://doi.org/10.1109/TIA.2021.3103923