Operating Limits for Low-Capacitance Cascaded H-Bridge Static Compensators.

Authors :
Rodriguez Ramos, Ezequiel
Leyva, Ramon
Farivar, Glen
Townsend, Christopher
Pou, Josep
Source :
IEEE Transactions on Power Electronics. Mar2022, Vol. 37 Issue 3, p3421-3433. 13p.
Publication Year :
2022

Abstract

The cascaded H-bridge (CHB) low-capacitance static compensator (LC-StatCom) has a limited inductive region compared to a conventional StatCom, both in balanced and unbalanced conditions, due to the inherent large oscillations on the capacitor voltages. This article presents a detailed analysis of the viable operating region in these converters that takes into account the inherent large oscillations. The analysis facilitates sizing of the dc-link capacitors to ensure that the StatCom is able to inject a given range of positive- and negative-sequence current. Though the analysis is generic and applicable to the CHB StatComs with relatively large capacitance values, it is more relevant in the LC-StatComs. In addition, the article derives reference steady-state signals that can be used as feedforward terms in LC-StatCom control loops to enhance the control performance. The article presents simulation and experimental results, in balanced and unbalanced conditions to corroborate the proposed analysis. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08858993
Volume :
37
Issue :
3
Database :
Academic Search Index
Journal :
IEEE Transactions on Power Electronics
Publication Type :
Academic Journal
Accession number :
153953282
Full Text :
https://doi.org/10.1109/TPEL.2021.3111201