Point of care testing using rapid automated antigen testing for SARS-COV-2 in care homes – an exploratory safety, usability and diagnostic agreement evaluation.

Authors :
Micocci, Massimo
Buckle, Peter
Hayward, Gail
Allen, A Joy
Davies, Kerrie
Kierkegaard, Patrick
Spilsbury, Karen
Thompson, Carl
Astle, Anita
Heath, Ros
Sharpe, Claire
Akrill, Cyd
Lasserson, Dan
Perera, Rafael
Body, Richard
Gordon, Adam L
Source :
Journal of Patient Safety & Risk Management. Dec2021, Vol. 26 Issue 6, p243-250. 8p.
Publication Year :
2021

Abstract

Introduction: Successful adoption of POCTs (Point-of-Care tests) for COVID-19 in care homes requires the identification of ideal use cases and a full understanding of the contextual and usability factors that affect test results and minimise biosafety risks. This paper presents a scoping-usability and test performance study of a microfluidic immunofluorescence assay for COVID-19 in care homes. Methods: A mixed-methods evaluation was conducted in four UK care homes to scope usability and to assess the agreement with qRT-PCR. A dry run with luminescent dye was conducted to explore biosafety issues. Results: The agreement analysis was conducted on 227 asymptomatic participants (159 staff and 68 residents) and 14 symptomatic participants (5 staff and 9 residents). Asymptomatic specimens showed 50% (95% CI:1.3%−98.7%) positive agreement and 96% (95% CI: 92.5%−98.1%) negative agreement with overall prevalence and bias-adjusted Kappa (PABAK) of 0.911 (95% CI: 0.857−0.965). Symptomatic specimens showed 83.3% (95% CI: 35.9%−99.6%) positive agreement and 100% (95% CI: 63.1%−100%) negative agreement with overall prevalence and bias-adjusted Kappa (PABAK) of 0.857 (95% CI: 0.549−1). The dry run highlighted four main sources of contamination that led to the modification of the standard operating procedures. Simulation post-modification showed no further evidence of contamination. Conclusion: Careful consideration of biosafety issues and contextual factors associated with care home are mandatory for safe use the POCT. Whilst POCT may have some utility for ruling out COVID-19, further diagnostic accuracy evaluations are needed to promote effective adoption. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
25160435
Volume :
26
Issue :
6
Database :
Academic Search Index
Journal :
Journal of Patient Safety & Risk Management
Publication Type :
Academic Journal
Accession number :
154068066
Full Text :
https://doi.org/10.1177/25160435211054207