Back to Search
Start Over
A High Spatial Resolution Muon Tomography Prototype System Based on Micromegas Detector.
- Source :
-
IEEE Transactions on Nuclear Science . Jan2022, Vol. 69 Issue 1, p78-85. 8p. - Publication Year :
- 2022
-
Abstract
- Cosmic ray muon has strong penetrating power and no ionizing radiation hazards, which makes it an ideal probe for detecting special nuclear materials (SNMs). In this article, a high spatial resolution muon tomography system based on Micromegas detectors is proposed to optimize the imaging time and quality. The proposed system includes eight Micromegas detectors based on the thermal bonding technique and a scalable readout system. In addition, a multiplexing method based on position encoding is developed to reduce the number of electronics channels by order of magnitude. The spatial resolution of the proposed system with encoding readout can reach a value of hundred micrometers. Finally, a tomography test is performed, and test results show that this proposed system can image 2-cm objects and distinguish different materials. [ABSTRACT FROM AUTHOR]
- Subjects :
- *MUONS
*COSMIC ray muons
*SPATIAL resolution
*TOMOGRAPHY
*DETECTORS
Subjects
Details
- Language :
- English
- ISSN :
- 00189499
- Volume :
- 69
- Issue :
- 1
- Database :
- Academic Search Index
- Journal :
- IEEE Transactions on Nuclear Science
- Publication Type :
- Academic Journal
- Accession number :
- 154862005
- Full Text :
- https://doi.org/10.1109/TNS.2021.3137415