Back to Search Start Over

Disaggregation of electricity and heating consumption in commercial buildings with building automation system data.

Authors :
Zaeri, Narges
Ashouri, Araz
Gunay, H. Burak
Abuimara, Tareq
Source :
Energy & Buildings. Mar2022, Vol. 258, pN.PAG-N.PAG. 1p.
Publication Year :
2022

Abstract

• A method is to disaggregate bulk meter data of commercial buildings into end uses. • The method uses building automation system data to disaggregate bulk energy use. • The method is demonstrated with data from a submetered academic office building. • The method accurately disaggregated the heating and electricity end uses. Although understanding end uses in large commercial and institutional buildings is of great utility for achieving energy efficiency, most new and existing buildings still lack adequate submetering except for large end uses. End use disaggregation methods offer an alternative to fulfill weaknesses in a metering network, especially in large commercial and institutional buildings. Unlike non-intrusive load monitoring (NILM) methods that mostly rely on high frequency power consumption data and focus on residential buildings, this paper introduces an end-use disaggregation approach using building automation system (BAS) data. The BAS data provide information about the operational status of main energy-consuming systems and equipment such as fans, pumps, air handling unit (AHU) heating coils, and variable air volume (VAV) terminal reheat coils. The proposed method uses a suite of multiple linear regression models estimated by the genetic algorithm and a least-square solver to disaggregate heating and electricity use data using BAS data as predictors. The method was demonstrated with data from an academic office building in Ottawa, Canada. The accuracy was evaluated by comparing the disaggregation results to ground truth energy use data acquired from dedicated submeters. The findings suggest that the method can accurately disaggregate building-level hourly electricity and heating energy use into following end use categories, for electricity: (a) occupant-controlled loads (lighting and plug loads), (b) distribution loads (the electricity used by the AHUs); and for heating: (a) energy used by the AHU heating coils, (b) perimeter heating devices (reheat coils/and radiators). [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03787788
Volume :
258
Database :
Academic Search Index
Journal :
Energy & Buildings
Publication Type :
Academic Journal
Accession number :
155189501
Full Text :
https://doi.org/10.1016/j.enbuild.2021.111791