Near‐infrared spectroscopy (NIRS) allows innovative applications in terms of quality control, for example, in raw materials verification, in process analytical technology (PAT), and in discrimination between genuine and falsified medicines. The development of small and cheap handheld devices is expanding in the field, while trying to keep similar performances as benchtop instruments have. Considering traceability and quality control of drug compounds, this work is intended to identify 13 different paracetamol tablets on the Belgian market by using NIRS. The performances of a Fourier‐transform near‐infrared spectroscopy (FT‐NIR) benchtop and two handheld NIR spectrometers were investigated comparatively. All spectra were collected through the blister in the reflectance diffuse mode. NIR spectral fingerprints were pretreated and analyzed using principal component analysis (PCA) and classified with soft independent modeling of class analogy (SIMCA). The performances of the spectrometers were evaluated after standardization of the reference benchtop database to the handheld spectrometers. The instrumental response of the benchtop spectrometer was standardized towards the handheld device using the piecewise direct standardization (PDS) algorithm. These investigations permitted the advantages and limitations of NIR data standardization on predictive models to be pointed out. The SIMCA models based on the spectral data of the benchtop (B), handheld 1 (H1), and handheld 2 (H2) instruments had an accuracy of 99.2%, 97.7%, and 96.2%, respectively. The same accuracy was obtained with the models of the transferred benchtop spectra for the H1 and H2 devices. However, adding handheld spectra to the transferred benchtop spectra resulted in models with improved accuracy: from 97.7% to 98.5% for the H1 instrument and from 96.2% to 97.7% for the H2 instrument. The proposed strategy highlights the potential of using a reference database collected by NIRS for pharmaceutical analyses by handheld NIR spectrometers in terms of traceability. The study presented in this work aimed to highlight the potential of handheld devices to discriminate pharmaceutical formulations, using a standardized reference database. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08869383
Volume :
36
Issue :
3
Database :
Academic Search Index
Journal :
Journal of Chemometrics
Publication Type :
Academic Journal
Accession number :
155759679
Full Text :
https://doi.org/10.1002/cem.3389