Back to Search
Start Over
Early failure of a tricuspid valve replacement with a mitral valve homograft in a heart transplant recipient
- Source :
-
Journal of Heart & Lung Transplantation . Dec2004, Vol. 23 Issue 12, p1460-1462. 3p. - Publication Year :
- 2004
-
Abstract
- A 24-year-old woman experienced severe tricuspid valve regurgitation 6 years after heart transplantation. Tricuspid valve replacement was performed using a cryopreserved mitral valve homograft. Severe tricuspid valve regurgitation recurred within 4 months, associated with an increase in the panel reactive antibody titers from zero to 72%. Tricuspid valve replacement was repeated with a porcine bioprosthesis with excellent recovery and function for >2 years. The mitral valve homograft displayed inflammatory features consistent with humoral immune-mediated destruction. [Copyright &y& Elsevier]
Details
- Language :
- English
- ISSN :
- 10532498
- Volume :
- 23
- Issue :
- 12
- Database :
- Academic Search Index
- Journal :
- Journal of Heart & Lung Transplantation
- Publication Type :
- Academic Journal
- Accession number :
- 15647709
- Full Text :
- https://doi.org/10.1016/j.healun.2003.10.010