Back to Search Start Over

Diagnostic value of congenital pulmonary airway malformation volume ratio for fetal hydrops due to congenital lung malformations: a systematic review and meta-analysis.

Authors :
Zhu, Pei
Cheng, Kaisheng
He, Mingsheng
Wang, Yutong
Shen, Pengyue
He, Kanglin
Xu, Chang
Zhang, Ben
Liu, Zhenmi
Source :
Orphanet Journal of Rare Diseases. 6/3/2022, Vol. 17 Issue 1, p1-10. 10p.
Publication Year :
2022

Abstract

<bold>Objective: </bold>Meta-analysis was used to evaluate the diagnostic value of a CVR cut-off value of 1.6 for fetal hydrops due to congenital lung malformation (CLM).<bold>Methods: </bold>A systematic search of PubMed, Embase, Web of Science, CNKI, VIP, and Wanfang published before 7/30/2021 for the value of a congenital pulmonary airway malformation volume ratio (CVR) cut-off value of 1.6 for the diagnosis of fetal hydrops. According to the inclusion and exclusion criteria, the literature that met the requirements were obtained. A total of 75 articles were retrieved, and 12 articles were included for further analysis. The quality of these studies was evaluated according to the Quality Assessment for Studies of Diagnostic Accuracy tool (QUADAS-2) criteria. The Q test and heterogeneity I2 were used to evaluate the heterogeneity due to non-threshold effects, and Stata 15.0 was used for statistical analysis to evaluate the diagnostic value of the CVR cutoff value of 1.6 for fetal hydrops due to CLM.<bold>Results: </bold>A total of 12 studies were included. The QUADAS-2 indicated that the risk of bias was relatively low, and the clinical applicability was relatively high. Statistical analysis was performed on included studies using a random effect model. Meta-analysis showed that the pooled sensitivity, specificity, diagnostic ratio and summary receiver operating characteristic (SROC) for the diagnosis of fetal hydrops by CVR were 0.86 (95% CI, 0.72-0.93; I2 = 59.84), 0.90 (95% CI, 0.88-0.93; I2 = 31.94), 58 (95% CI, 22-149; I2 = 100%), 0.93 (95% CI, 0.91-0.95).<bold>Conclusions: </bold>The sensitivity and specificity of CVR cut-off value 1.6 for the diagnosis of CLM-induced fetal hydrops were high, no publication bias was observed, and the CVR cut-off value 1.6 is meaningful for the early diagnosis prediction of CLM-induced fetal hydrops. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
17501172
Volume :
17
Issue :
1
Database :
Academic Search Index
Journal :
Orphanet Journal of Rare Diseases
Publication Type :
Academic Journal
Accession number :
157261695
Full Text :
https://doi.org/10.1186/s13023-022-02347-0