Back to Search Start Over

DROPLET SIZE DISTRIBUTIONS FROM HOLLOW-CONE NOZZLES COUPLED WITH PWM VALVES.

Authors :
Salcedo, Ramón
Heping Zhu
Hongyoung Jeon
Ozkan, Erdal
Zhiming Wei
Gil, Emilio
Campos, Javier
Román, Carla
Source :
Journal of the ASABE. 2022, Vol. 65 Issue 4, p695-706. 12p.
Publication Year :
2022

Abstract

Integration of variable-rate disc-core nozzles in orchard sprayers is the optimal solution to achieve precision spray applications of agrochemicals; however, little information is available on the droplet size distribution and classification for these hollow-cone nozzles. Investigations were performed for the comprehensive understanding of spray droplet size spectrum discharged from hollow-cone nozzles which were manipulated with pulse width modulation (PWM) valves to produce variable flow rates. Test variables included five disc-core hollow-cone nozzle sizes (D2-DC25, D2-DC45, D4-DC25, D4-DC45, and D5-DC25), two 10-Hz PWM valve designs, five operating pressures (276, 414, 552, 689, and 827 kPa), and 10 duty cycles (DUCs) ranging from 10% to 100% at 10% intervals. Droplet diameters were measured with a laser imaging particle system. Volumetric diameters (DV0.1, DV0.5, and DV0.9) varied greatly with the nozzle orifice size, operating pressure, and DUC, and varied slightly by PWM valve type. Higher operating pressures and larger nozzles generated droplets with more consistent size distributions across DUCs from 10% to 100%. The differences in relative spans among DUCs increased with the nozzle size increase and the operating pressure decrease. Droplet size classifications from very fine to coarse, based on ASABE 572.3 standard definitions, varied with the nozzle size and operating pressure but were similar for two PWM valve designs at all DUCs. Spray volume fractions also varied with the droplet size range, DUC and pressure. For droplets smaller than 100 µm, the volume fraction remained relatively consistent or slightly decreased as DUC increased, but increased as the pressure increased. In comparison, the fraction increased as both DUC and pressure increased for droplets between 100 and 300 µm and decreased for the portion of droplets greater than 300 µm. As a result, the discovered information would be implemented for the improvement of precision variable-rate spray systems equipped with PWM valves. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
27693295
Volume :
65
Issue :
4
Database :
Academic Search Index
Journal :
Journal of the ASABE
Publication Type :
Academic Journal
Accession number :
158227781
Full Text :
https://doi.org/10.13031/ja.15064