Back to Search Start Over

Removal of heavy metals from industrial wastewater using microbial fuel cell.

Authors :
Al‐Asheh, Sameer
Bagheri, Marzieh
Aidan, Ahmad
Source :
Engineering in Life Sciences. Aug2022, Vol. 22 Issue 8, p535-549. 15p.
Publication Year :
2022

Abstract

Removal efficiency of gold from a solution of pure tetrachloroaurate ions was investigated using microbial fuel cell (MFC) technology. The effects of type of catholyte solution and initial gold concentration on the removal efficiency were considered. Due to its presence at high levels in the gold wastewater, the effect of copper ions on the removal efficiency of the gold ions was also studied. The effects of pH and initial biomass concentration on the gold removal efficiency was also determined. The results showed that after 5 h contact time, 95% of gold removal efficiency from a wastewater containing 250 ppm of initial gold ions at ambient temperature using 80 g/L yeast concentration was achieved. After 48 h of the cell's operation under the same condition, 98.86% of AuCl4– ions were successfully removed from the solution. At initial gold concentration in the waste solution of 250 ppm, pH 2, and initial yeast concentration of 80 g/L, 100% removal efficiency of the gold was achieved. On the other hand, the most suitable condition for copper removal was found at a pH of 5.2, where 53% removal efficiency from the waste solution was accomplished. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
16180240
Volume :
22
Issue :
8
Database :
Academic Search Index
Journal :
Engineering in Life Sciences
Publication Type :
Academic Journal
Accession number :
158342332
Full Text :
https://doi.org/10.1002/elsc.202200009