Back to Search Start Over

Accuracy of virtual crossmatch (VXM) prediction of physical crossmatch (PXM) results of donor specific antibody (DSA) in routine pretransplant settings–a single-center experience.

Authors :
Olszowska-Zaremb, Natasza
Zagożdżon, Radosław
Gozdowska, Jolanta
Source :
Transplant Immunology. Jun2022, Vol. 72, p1-5. 5p.
Publication Year :
2022

Abstract

Background Virtual crossmatch (VXM) is a new powerful tool in pre-transplant risk assessment. However, the ability of VXM to predict physical crossmatch (PXM) results remains controversial. Our work evaluated the predictive potential of VXM results, measured by SAB (single antigen bead assay), for CDCXM (complement-dependent cytotoxicity crossmatch) and FLXM (flow cytometry crossmatch) results of DSA (donor specific antibody) in sensitized patients. Methods In total, 261 CDCXM and FLXM measurements were performed for 180 potential kidney transplant candidates, each with a single HLA-A, single bondB, or -DR DSA against a potential deceased donor. Analysis was conducted with two SAB datasets of four-month distant and collected prior to and after PXM results. Optimal MFI (mean fluorescence intensity) thresholds and likelihood ratios were assigned based on low (<2000 MFI), medium (2001–5000 MFI) and high risk (>5000 MFI). The impact of VXM predictability was determined by the ROC curves comparison. In addition, inter-assay changes of MFI were evaluated. Results The accuracy of VXM to predict CDCXM was inferior to that of FLXM with the AUC (area under ROC curve) of 0.644 vs. 0.849. In contrast, the initial ROC analysis showed that the VXM prediction was good for both T-FLXM with ROC value of 0.849 and by B-FLXM with ROC value of 0.706 for a single antigen of HLA-A, single bondB, or -DR DSA. In fact, the best VXM prediction was for FLXM with good sensitivity for B-FLXM against HLA-DR-specific DSA (0.851). Similar results of VXM predictability were observed for pre- and post-crossmatch ROC curves. Conclusion VXM predictability is better for positive/negative FLXM than for positive/negative CDCXM results to evaluate a single HLA-A, single bondB, -DR DSA disparity. This may be related to the fact that VXM and FLXM rely on binding of antibodies to beads or cells, respectively. In contrast, VXM is less predictive for CDCXM because the latter measures complement-dependent cytotoxic function. We intend expand VXM analysis to correlate their results with FLXM re [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09663274
Volume :
72
Database :
Academic Search Index
Journal :
Transplant Immunology
Publication Type :
Academic Journal
Accession number :
158344673
Full Text :
https://doi.org/10.1016/j.trim.2022.101583