Back to Search Start Over

Effective Low Magnetic Field J c (B) Scaling of ITER Nb 3 Sn Strands by Magnetization and Critical Current Measurements.

Authors :
Huang, Jianfeng
Ilyin, Yury
Bessette, Denis
Zhou, Chao
Lubkemann, Ruben
Vermeer, Cris
Wessel, W. A. J.
Nijhuis, Arend
Source :
IEEE Transactions on Applied Superconductivity. Nov2022, Vol. 32 Issue 8, p1-10. 10p.
Publication Year :
2022

Abstract

For the International Thermonuclear Experimental Reactor magnets, a significant fraction of the Nb3Sn conductors will be operating at a low field (B < 4 T), such as the outer turns of the central solenoid modules and toroidal field winding packs, while so far, the Ic(B,T, Ɛ) parameterization has been derived from measurements carried out at higher fields (B ≥ 7 T). It may not be accurate enough to adopt this parameterization for the extrapolation of the conductors’ operating performance in terms of critical current (Ic) and current sharing (Tcs). The critical current characteristic can be effectively extended to the lower field region by means of a relation between the magnetization and critical current. The parameterization of the derived critical current scaling law Jc(B) is processed for the field range of the magnetization measurement (0 < B ≤ 9 T) and the critical current measurements (7 ≤ B < 12 T) in order to cover the full range up to 12 T. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10518223
Volume :
32
Issue :
8
Database :
Academic Search Index
Journal :
IEEE Transactions on Applied Superconductivity
Publication Type :
Academic Journal
Accession number :
158803871
Full Text :
https://doi.org/10.1109/TASC.2022.3190921