Back to Search Start Over

Artificial intelligence software standardizes electrogram‐based ablation outcome for persistent atrial fibrillation.

Authors :
Seitz, Julien
Durdez, Théophile Mohr
Albenque, Jean P.
Pisapia, André
Gitenay, Edouard
Durand, Cyril
Monteau, Jacques
Moubarak, Ghassan
Théodore, Guillaume
Lepillier, Antoine
Zhao, Alexandre
Bremondy, Michel
Maluski, Alexandre
Cauchemez, Bruno
Combes, Stéphane
Guyomar, Yves
Heuls, Sébastien
Thomas, Olivier
Penaranda, Guillaume
Siame, Sabrina
Source :
Journal of Cardiovascular Electrophysiology. Nov2022, Vol. 33 Issue 11, p2250-2260. 11p. 1 Diagram, 3 Charts, 4 Graphs.
Publication Year :
2022

Abstract

Introduction: Multiple groups have reported on the usefulness of ablating in atrial regions exhibiting abnormal electrograms during atrial fibrillation (AF). Still, previous studies have suggested that ablation outcomes are highly operator‐ and center‐dependent. This study sought to evaluate a novel machine learning software algorithm named VX1 (Volta Medical), trained to adjudicate multipolar electrogram dispersion. Methods: This study was a prospective, multicentric, nonrandomized study conducted to assess the feasibility of generating VX1 dispersion maps. In 85 patients, 8 centers, and 17 operators, we compared the acute and long‐term outcomes after ablation in regions exhibiting dispersion between primary and satellite centers. We also compared outcomes to a control group in which dispersion‐guided ablation was performed visually by trained operators. Results: The study population included 29% of long‐standing persistent AF. AF termination occurred in 92% and 83% of the patients in primary and satellite centers, respectively, p = 0.31. The average rate of freedom from documented AF, with or without antiarrhythmic drugs (AADs), was 86% after a single procedure, and 89% after an average of 1.3 procedures per patient (p = 0.4). The rate of freedom from any documented atrial arrhythmia, with or without AADs, was 54% and 73% after a single or an average of 1.3 procedures per patient, respectively (p < 0.001). No statistically significant differences between outcomes of the primary versus satellite centers were observed for one (p = 0.8) or multiple procedures (p = 0.4), or between outcomes of the entire study population versus the control group (p > 0.2). Interestingly, intraprocedural AF termination and type of recurrent arrhythmia (i.e., AF vs. AT) appear to be predictors of the subsequent clinical course. Conclusion: VX1, an expertise‐based artificial intelligence software solution, allowed for robust center‐to‐center standardization of acute and long‐term ablation outcomes after electrogram‐based ablation. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10453873
Volume :
33
Issue :
11
Database :
Academic Search Index
Journal :
Journal of Cardiovascular Electrophysiology
Publication Type :
Academic Journal
Accession number :
160149553
Full Text :
https://doi.org/10.1111/jce.15657