Back to Search Start Over

Segmentation-guided Denoising Network for Low-dose CT Imaging.

Authors :
Huang, Zhenxing
Liu, Zhou
He, Pin
Ren, Ya
Li, Shuluan
Lei, Yuanyuan
Luo, Dehong
Liang, Dong
Shao, Dan
Hu, Zhanli
Zhang, Na
Source :
Computer Methods & Programs in Biomedicine. Dec2022, Vol. 227, pN.PAG-N.PAG. 1p.
Publication Year :
2022

Abstract

• Structural semantic information is introduced in LDCT domain • Structural semantic loss function is designed for network training • Semantic evaluation metric is applied for image quality assessment. Background: To reduce radiation exposure and improve diagnosis in low-dose computed tomography, several deep learning (DL)-based image denoising methods have been proposed to suppress noise and artifacts over the past few years. However, most of them seek an objective data distribution approximating the gold standard and neglect structural semantic preservation. Moreover, the numerical response in CT images presents substantial regional anatomical differences among tissues in terms of X-ray absorbency. Methods: In this paper, we introduce structural semantic information for low-dose CT imaging. First, the regional segmentation prior to low-dose CT can guide the denoising process. Second the structural semantical results can be considered as evaluation metrics on the estimated normal-dose CT images. Then, a semantic feature transform is engaged to combine the semantic and image features on a semantic fusion module. In addition, the structural semantic loss function is introduced to measure the segmentation difference. Results: Experiments are conducted on clinical abdomen data obtained from a clinical hospital, and the semantic labels consist of subcutaneous fat, muscle and visceral fat associated with body physical evaluation. Compared with other DL-based methods, the proposed method achieves better performance on quantitative metrics and better semantic evaluation. Conclusions: The quantitative experimental results demonstrate the promising performance of the proposed methods in noise reduction and structural semantic preservation. While, the proposed method may suffer from several limitations on abnormalities, unknown noise and different manufacturers. In the future, the proposed method will be further explored, and wider applications in PET/CT and PET/MR will be sought. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01692607
Volume :
227
Database :
Academic Search Index
Journal :
Computer Methods & Programs in Biomedicine
Publication Type :
Academic Journal
Accession number :
160436344
Full Text :
https://doi.org/10.1016/j.cmpb.2022.107199