Back to Search Start Over

凝血检验报告自动审核系统的建立与应用评价.

Authors :
杨冬梅
夏春燕
骆亭君
王艺晓
晋 臻
Source :
Journal of Kunming Medical University / Kunming Yike Daxue Xuebao. 2022, Vol. 43 Issue 11, p58-62. 5p.
Publication Year :
2022

Abstract

Objective To establish an automatic review system for blood coagulation test report and evaluate its application effect. Methods The rules for the examination of coagulation test reports were written into Lis Procedure. A total of 6 281 reports that were automatically audited during the commissioning period were selected for manual verification, to evaluate the feasibility of the rules. Results The passing rate of automatic verification was 71.34%, False positive rate (4.49%), False negative rate (0.032%), Positive coincidence rate (24.14%), Negative coincidence rate ( 71.34%), Consistent rate ( 95.48%) and correct passing rate ( 99.96%). Conclusion There are 23 intercepting rules, the Delta Check rule of APTT needs to be improved, and the rest of 22 intercepting rules’ correct passing rate is 100%. [ABSTRACT FROM AUTHOR]

Details

Language :
Chinese
ISSN :
2095610X
Volume :
43
Issue :
11
Database :
Academic Search Index
Journal :
Journal of Kunming Medical University / Kunming Yike Daxue Xuebao
Publication Type :
Academic Journal
Accession number :
160746320
Full Text :
https://doi.org/10.12259/j.issn.2095-610X.S20221107