Back to Search
Start Over
Research on Self-Noise Characteristics of Nine Types of Seismometers Obtained by PDF Representation Using Continuous Seismic Data from the Malingshan Seismic Station, China.
- Source :
-
Sensors (14248220) . Jan2023, Vol. 23 Issue 1, p110. 15p. - Publication Year :
- 2023
-
Abstract
- The self-noise level of a seismometer can determine the performance of the seismic instrument and limit the ability to use seismic data to solve geoscience problems. Accurately measuring and simultaneously comparing the self-noise models from different types of seismometers has long been a challenging task due to the constraints of observation conditions. In this paper, the self-noise power spectral density (PSD) values of nine types of seismometers are calculated using four months of continuous seismic waveforms from Malingshan seismic station, China, and nine self-noise models are obtained based on the probability density function (PDF) representation. For the seismometer STS-2.5, the self-noise levels on the horizontal channels (E–W and N–S) are significantly higher than that on the vertical channel (U–D) in the microseism band (0.1 Hz to 1 Hz), which is a computing bias caused by the misalignment between the sensors in the horizontal direction, while the remarkably elevated noise on the horizontal channels at the low frequencies (<0.6 Hz) may originate from the local variation of atmospheric pressure. As for the very broadband seismometers Trillium-Horizon-120 and Trillium-120PA, and the ultra-broadband seismometers Trillium-Horizon-360 and CMG-3T-360, there is a trade-off between the microseism band range and low-frequency range in the PSD curves of the vertical channel. When the level of self-noise in the microseism band is high, the self-noise at low frequencies is relatively low. Although compared with the other very broadband seismometers, the self-noise level of the vertical component of the STS-2.5 is 3 dB to 4 dB lower at frequencies less than 1 Hz, the self-noise level of the STS-2.5 at high frequencies (>2 Hz) is slightly higher than others. From our observations, we conclude that the nine seismometers cannot reach the lowest noise level in all frequency bands within the working range. [ABSTRACT FROM AUTHOR]
- Subjects :
- *MICROSEISMS
*SEISMOMETERS
*PROBABILITY density function
*ATMOSPHERIC pressure
Subjects
Details
- Language :
- English
- ISSN :
- 14248220
- Volume :
- 23
- Issue :
- 1
- Database :
- Academic Search Index
- Journal :
- Sensors (14248220)
- Publication Type :
- Academic Journal
- Accession number :
- 161185821
- Full Text :
- https://doi.org/10.3390/s23010110