Back to Search Start Over

Absolute Radiometric Calibration of ZY3-02 Satellite Multispectral Imager Based on Irradiance-Based Method.

Authors :
Tang, Hongzhao
Xie, Junfeng
Chen, Wei
Zhang, Honggeng
Wang, Hengyang
Source :
Remote Sensing. Jan2023, Vol. 15 Issue 2, p448. 14p.
Publication Year :
2023

Abstract

In this paper, an irradiance-based absolute radiometric calibration campaign at Baotou calibration site during June and July 2018 was described. This radiometric calibration campaign made use of six radiometric calibration tarps. The synchronous measurements of parameters such as surface reflectance, atmospheric parameters, and diffuse-to-global irradiance ratio were collected at the satellite overpass. The top-of-atmospheric radiance was predicted by radiative transfer model with these synchronous measurements. The linear relationship between DNs of satellite sensor and band-specific top-of-atmospheric spectral radiance was established, and a stable and reliable absolute calibration coefficient of ZY3-02 MUX was determined in this campaign. We compared the calibration results of the irradiance-based method with those of the reflectance-based method. The results suggested that the irradiance-based method is better than reflectance-based method. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20724292
Volume :
15
Issue :
2
Database :
Academic Search Index
Journal :
Remote Sensing
Publication Type :
Academic Journal
Accession number :
161479462
Full Text :
https://doi.org/10.3390/rs15020448