Back to Search
Start Over
[18F]mFBG PET-CT for detection and localisation of neuroblastoma: a prospective pilot study.
- Source :
-
European Journal of Nuclear Medicine & Molecular Imaging . Mar2023, Vol. 50 Issue 4, p1146-1157. 12p. 1 Color Photograph, 2 Black and White Photographs, 2 Charts, 1 Graph. - Publication Year :
- 2023
-
Abstract
- Purpose: Meta-[18F]fluorobenzylguanidine ([18F]mFBG) is a positron emission tomography (PET) radiotracer that allows for fast and high-resolution imaging of tumours expressing the norepinephrine transporter. This pilot study investigates the feasibility of [18F]mFBG PET-CT for imaging in neuroblastoma. Methods: In a prospective, single-centre study, we recruited children with neuroblastoma, referred for meta-[123I]iodobenzylguanidine ([123I]mIBG) scanning, consisting of total body planar scintigraphy in combination with single-photon emission computed tomography-CT (SPECT-CT). Within two weeks of [123I]mIBG scanning, total body PET-CTs were performed at 1 h and 2 h after injection of [18F]mFBG (2 MBq/kg). Detected tumour localisations on scan pairs were compared. Soft tissue disease was quantified by number of lesions and skeletal disease by SIOPEN score. Results: Twenty paired [123I]mIBG and [18F]mFBG scans were performed in 14 patients (median age 4.9 years, n = 13 stage 4 disease and n = 1 stage 4S). [18F]mFBG injection was well tolerated and no related adverse events occurred in any of the patients. Mean scan time for [18F]mFBG PET-CT (9.0 min, SD 1.9) was significantly shorter than for [123I]mIBG scanning (84.5 min, SD 10.5), p < 0.01. Most tumour localisations were detected on the 1 h versus 2 h post-injection [18F]mFBG PET-CT. Compared to [123I]mIBG scanning, [18F]mFBG PET-CT detected a higher, equal, and lower number of soft tissue lesions in 40%, 55%, and 5% of scan pairs, respectively, and a higher, equal, and lower SIOPEN score in 55%, 30%, and 15% of scan pairs, respectively. On average, two more soft tissue lesions and a 6-point higher SIOPEN score were detected per patient on [18F]mFBG PET-CT compared to [123I]mIBG scanning. Conclusion: Results of this study demonstrate feasibility of [18F]mFBG PET-CT for neuroblastoma imaging. More neuroblastoma localisations were detected on [18F]mFBG PET-CT compared to [123I]mIBG scanning. [18F]mFBG PET-CT shows promise for future staging and response assessment in neuroblastoma. Trial registration: Dutch Trial Register NL8152. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 16197070
- Volume :
- 50
- Issue :
- 4
- Database :
- Academic Search Index
- Journal :
- European Journal of Nuclear Medicine & Molecular Imaging
- Publication Type :
- Academic Journal
- Accession number :
- 161898993
- Full Text :
- https://doi.org/10.1007/s00259-022-06063-6