Improved closed test setup for biodegradation testing of slightly volatile substances in water-sediment systems (OECD 308).

Authors :
Shrestha, Prasit
Hughes, Christopher B.
Camenzuli, Louise
Lyon, Delina
Meisterjahn, Boris
Hennecke, Thomas
Griffiths, Megan
Hennecke, Dieter
Source :
Chemosphere. May2023, Vol. 324, pN.PAG-N.PAG. 1p.
Publication Year :
2023

Abstract

Standardized biodegradation testing methods, like the OECD 308 Aerobic and Anaerobic Transformation in Aquatic Sediment Systems, generate data on biodegradation required during environmental risk and hazard assessment of chemicals under different European and international regulations. However, difficulties arise when applying the OECD 308 guideline for testing hydrophobic volatile chemicals. Especially the use of a co-solvent (like acetone) as a measure to facilitate the application of the test chemical in combination with a closed setup to reduce losses due to volatilization tend to deplete/restrict the amount of oxygen in the test system. The result is a low oxygen or even anoxic water column in the water-sediment system. Thus, the degradation half-lives of the chemical generated from such tests are not directly comparable to the regulatory half-life values for Persistence assessment of the test chemical. The aim of this work was to further develop the closed setup to improve and maintain aerobic conditions in the water phase of the water-sediment systems for testing slightly volatile hydrophobic test chemicals. This improvement was attained by optimizing the test system geometry and agitation technique to maintain aerobic conditions in the water phase in a closed test setup, investigating appropriate co-solvent application strategy, and trialing the resulting test setup. This study shows that when using a closed test setup for OECD 308 tests, agitation of the water phase overlaying the sediment and the test item application using low co-solvent volume is critical for maintaining an aerobic water layer. [Display omitted] • Agitation of the water-sediment sample without/limited sediment resuspension. • Use of co-solvent for application should be limited while testing volatiles using closed setup. • Improved closed setup results in stable aerobic conditions and higher degradation. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00456535
Volume :
324
Database :
Academic Search Index
Journal :
Chemosphere
Publication Type :
Academic Journal
Accession number :
162538163
Full Text :
https://doi.org/10.1016/j.chemosphere.2023.138294