Back to Search Start Over

Study on the purification of indoor gas pollutants by O3/Fe-Ti02/UV.

Authors :
JIA Guan-guan
ZHANG Xing-hui
GAO Xin
HU Hao
Source :
Applied Chemical Industry. Feb2023, Vol. 52 Issue 2, p439-450. 7p.
Publication Year :
2023

Abstract

Hydrogen sulfide, ammonia, formaldehyde, toluene, n-pentane and acetone were used as indoor gas pollutants. Using ozone synergistic photocatalysis technology, Ti02 was selected as photocatalyst and doped with Fe3+, and the effects of TiO2 modification and different gas flow rate, initial reactant concentration, relative humidity and ozone concentration on purification efficiency were investigated. The results show that when the gas flow rate in the reaction section is 1 m/s,the amount of ozone is 49.08 mg/m³, the relative humidity is less than 50%, and the system runs for 30 min, the average purification efficiency of 03/Fe-Ti02/UV technology for six kinds of gas pollutants is 65%. [ABSTRACT FROM AUTHOR]

Details

Language :
Chinese
ISSN :
16713206
Volume :
52
Issue :
2
Database :
Academic Search Index
Journal :
Applied Chemical Industry
Publication Type :
Academic Journal
Accession number :
162614358