Back to Search Start Over

High peak inspiratory pressure may be associated with intraoperative coughing during neurosurgery under general anesthesia without neuromuscular blockade: a retrospective study.

Authors :
Oh, Hyongmin
Sohn, Jin Young
Ma, Seoyoung
Choi, Seungeun
Kim, Yoon Jung
Lee, Hyung-Chul
Lee, Chang-Hyun
Kim, Chi Heon
Chung, Chun Kee
Park, Hee-Pyoung
Source :
BMC Anesthesiology. 4/14/2023, Vol. 23 Issue 1, p1-10. 10p.
Publication Year :
2023

Abstract

Background: The endotracheal cuff pressure depends on the airway pressure during positive-pressure ventilation. A high endotracheal cuff pressure may be related to intraoperative coughing, which can be detrimental during neurosurgery. We investigated the incidence of intraoperative coughing and its association with peak inspiratory pressure (PIP) during neurosurgery under general anesthesia without neuromuscular blockade. Methods: This retrospective study divided 1656 neurosurgical patients who underwent total intravenous anesthesia without additional neuromuscular blockade after tracheal intubation into high (PIP > 21.6 cmH2O, n = 318) and low (PIP ≤ 21.6 cmH2O, n = 1338) PIP groups. After propensity score matching, 206 patients were selected in each group. Demographic, preoperative, surgical, and anesthetic data were collected retrospectively from electronic medical records and continuous ventilator, infusion pump, and bispectral index data from a data registry. Results: Intraoperative coughing occurred in 30 (1.8%) patients, including 9 (0.5%) during the main surgical procedure. Intraoperative coughing was more frequent in the high PIP group than in the low PIP group before (14/318 [4.4%] vs. 16/1338 [1.2%], P < 0.001) and after (13/206 [6.3%] vs. 1/206 [0.5%], P = 0.003) propensity score matching. In multivariable logistic regression analysis after propensity score matching, a high PIP (odds ratio [95% confidence interval] 14.22 [1.81-111.73], P = 0.012), tidal volume divided by predicted body weight (mL/kg, 1.36 [1.09–1.69], P = 0.006), and surgical duration (min, 1.01 [1.00–1.01], P = 0.025) predicted intraoperative coughing. Conclusion: The incidence of intraoperative coughing was 1.8% in neurosurgical patients undergoing general anesthesia without neuromuscular blockade and might be associated with a high PIP. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
14712253
Volume :
23
Issue :
1
Database :
Academic Search Index
Journal :
BMC Anesthesiology
Publication Type :
Academic Journal
Accession number :
163120106
Full Text :
https://doi.org/10.1186/s12871-023-02080-6