Ignition and combustion of a group of waste-derived fuel slurry droplets: Mutual influence upon low-temperature convective heating.
- Source :
-
Fuel . Sep2023, Vol. 348, pN.PAG-N.PAG. 1p. - Publication Year :
- 2023
-
Abstract
- [Display omitted] • Simultaneous ignition occurred at a distance between the droplet centers of 3–5 mm. • At low temperatures, increasing the distance between droplets eliminates synergism. • The use of an oil additive (5%) reduced the ignition delay time of droplets by 15–20%. • The increase in air flow velocity contributed to the formation of a common flame zone. • The ignition delay in the droplet group increased with an increase in air flow velocity. Waste-derived slurries can be burned both in a fluidized bed and when injected into a boiler furnace. This paper is the first to analyze the dynamic characteristics of ignition and combustion of a group of three slurry droplets based on coal slime, water, and waste industrial oil in a low-temperature air flow with a temperature of 500–600 °C and velocity of 0.1–1.2 m/s. The distance between the droplet centers varied from 3 to 15 mm. The results of the study can develop innovative technologies for flare and fluidized bed combustion of fuel slurries at the boiler start-up stage. It was found that a distance of 3–5 mm between droplet centers provides almost simultaneous gas-phase ignition of all droplets. A further increase in the distance critically worsened the ignition and combustion and eliminated the synergy. An increase in the air flow velocity contributed to the appearance of a common flame zone but at the same time increased the ignition delay of droplets by a factor of 1.2–1.6. The negative effects of cooling and entrainment of combustion products by a low-temperature flow can be effectively reduced by adding 5 wt% of industrial oil to the slurry. Also, the use of oil reduced the droplet ignition delay time by 15–20%. At the stages of flame and heterogeneous combustion, the differences for droplets in a group increased (the stage durations differed by 1.5–3 times). For the low-temperature start-up of a boiler, it was found advisable to provide a droplet flow with a sufficient density to stabilize their ignition without significant flow deviations (dimensionless distance 1.5–2.5). [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00162361
- Volume :
- 348
- Database :
- Academic Search Index
- Journal :
- Fuel
- Publication Type :
- Academic Journal
- Accession number :
- 163797705
- Full Text :
- https://doi.org/10.1016/j.fuel.2023.128578