Back to Search Start Over

Serum Ubiquitin C-Terminal Hydrolase-L1, Glial Fibrillary Acidic Protein, and Neurofilament Light Chain Are Good Entry Points and Biomarker Candidates for Neurosyphilis Diagnosis Among Patients Without Human Immunodeficiency Virus to Avoid Lumbar Puncture

Authors :
Xie, Lin
Li, Wei
Ye, Wei-Ming
Xiao, Yao
Ke, Wu-Jian
Niu, Jian-Jun
Yang, Tian-Ci
Source :
Clinical Infectious Diseases. Aug2023, Vol. 77 Issue 3, p472-479. 8p.
Publication Year :
2023

Abstract

Background Laboratory tests to diagnose neurosyphilis using cerebrospinal fluid (CSF) are currently disadvantageous as a lumbar puncture is required, which may result in patients with neurosyphilis missing an opportunity for early diagnosis. Thus, blood biomarker candidates that are more convenient and minimally invasive to collect for diagnosing neurosyphilis is urgently needed. Methods This observational study aimed to analyze serum ubiquitin C-terminal hydrolase-L1 (UCH-L1), glial fibrillary acidic protein (GFAP), and neurofilament light chain (NF-L) levels in 153 patients without human immunodeficiency virus (HIV) and to evaluate their diagnostic performance in neurosyphilis compared with CSF. Results Serum UCH-L1, GFAP, and NF-L levels were significantly higher in patients with neurosyphilis compared with patients with uncomplicated syphilis or non-syphilis. For the diagnosis of neurosyphilis, serum UCH-L1, GFAP, and NF-L revealed sensitivities of 90.20%, 80.40%, and 88.24%, and specificities of 92.16%, 78.43%, and 80.39%, respectively, at cutoff levels of 814.50 pg/mL, 442.70 pg/mL, and 45.19 pg/mL, respectively. In patients with syphilis, serum UCH-L1, GFAP, and NF-L levels correlated strongly or moderately with those in the CSF, with similar or better diagnostic performance than those in the CSF. The testing algorithms' sensitivity and specificity increased to 98.04% and 96.08%, respectively, when subjected to parallel and combination testing, respectively. Conclusions To avoid lumbar puncture, each serum UCH-L1, GFAP, and NF-L is a good entry point and biomarker candidate for the diagnosis of neurosyphilis among patients without HIV. These proteins used in concerto can further improve the diagnostic sensitivity and specificity. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10584838
Volume :
77
Issue :
3
Database :
Academic Search Index
Journal :
Clinical Infectious Diseases
Publication Type :
Academic Journal
Accession number :
169973921
Full Text :
https://doi.org/10.1093/cid/ciad158