Back to Search Start Over

A Simplified Lift-Off Correction for Three Components of the Magnetic Flux Leakage Signal for Defect Detection.

Authors :
Peng, Lisha
Huang, Songling
Wang, Shen
Zhao, Wei
Source :
IEEE Transactions on Instrumentation & Measurement. 2021, Vol. 70, p1-9. 9p.
Publication Year :
2021

Abstract

Magnetic flux leakage (MFL) testing is widely used to detect and estimate defect in ferromagnetic materials. The lift-off of sensors caused the weakening of the detected signal inevitably. Therefore, it is necessary to correct lift-off for the detected MFL signal. In this article, we analyze the approximate negative exponential relationship between the three components of MFL signal of the defect and the lift-off based on magnetic dipole analytical method and establish a simplified numerical calculation model of MFL signal based on the lift-off. A lift-off correction method is also proposed to revise the three components of the MFL signal at a suitable range of lift-off efficiently. In this method, an exponential function compensation is introduced and only the lift-off correction value is concerned. The validity of the correction method is verified by the 3-D MFL testing experiment for the ferromagnetic pipeline defects. The results demonstrate that the corrected MFL signals match the experimental signals well. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00189456
Volume :
70
Database :
Academic Search Index
Journal :
IEEE Transactions on Instrumentation & Measurement
Publication Type :
Academic Journal
Accession number :
170415193
Full Text :
https://doi.org/10.1109/TIM.2021.3058407