Back to Search Start Over

Investigating the Characteristic of Weak Magnetic Stress Internal Detection Signals of Long-Distance Oil and Gas Pipeline Under Demagnetization Effect.

Authors :
Liu, Bin
Zhang, He
Zhang, Baoping
Lian, Zheng
Yang, Lijian
Liu, Tong
Source :
IEEE Transactions on Instrumentation & Measurement. 2021, Vol. 70, p1-13. 13p.
Publication Year :
2021

Abstract

Studies show that the demagnetization effect of the pipeline wall affects the detection accuracy and detection range of the pipelines’ weak magnetic stress internal detection (WMSID). This study deals with mathematical modeling of the WMSID under the demagnetization effect. Moreover, the interference characteristics of the demagnetization effect on the weak magnetic signal (WMS) are analytically calculated, and the transfer features of WMSs are studied. Obtained results show that, in the transmission medium, the demagnetization effect produces an interfering magnetic field. It is found that performing the demagnetization effect calculation can reduce the calculation error of the mathematical model by 27.6%. Moreover, the demagnetization impact on the pipeline wall material complicates detecting the stress concentration zone (SCZ) on the pipeline’s outer wall. Normal component WMS has high stability in the pipeline wall material so that it is an appropriate choice for detecting the SCZ on the pipeline’s outer wall. Finally, the BiHill function is introduced to fit the excitation curve of the WMS. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00189456
Volume :
70
Database :
Academic Search Index
Journal :
IEEE Transactions on Instrumentation & Measurement
Publication Type :
Academic Journal
Accession number :
170415796
Full Text :
https://doi.org/10.1109/TIM.2021.3112782