Back to Search Start Over

Real-world data analysis of distributed PV and battery energy storage system curtailment in low voltage networks.

Authors :
Yildiz, Baran
Stringer, Naomi
Klymenko, Timothy
Syahman Samhan, Muhammad
Abramowitz, Greg
Bruce, Anna
MacGill, Iain
Egan, Renate
Sproul, Alistair B.
Source :
Renewable & Sustainable Energy Reviews. Oct2023, Vol. 186, pN.PAG-N.PAG. 1p.
Publication Year :
2023

Abstract

Curtailment of distributed photovoltaic (PV) and battery energy storage systems will have significant implications for power system transition around the world. Australia offers a unique case study as it has highest installation rate of distributed-PV and growing fleet of battery energy storage systems. Distributed-PV and battery inverters in Australia are required to exhibit voltage-responsive power-quality response modes to prevent excessive voltage rise caused by increasing day-time energy exports, but these modes can curtail power output and limit the value that can be gained from the renewable energy assets. For the first time in Australia, this paper studies all three inverter power-quality response modes and develops novel algorithms to assess curtailment. The algorithms are applied to a real-world dataset of 1-sec distributed-PV and battery power measurements from 1300 residential households; therefore, data resolution is higher and sample size is larger than previous related studies. Using these datasets, the study compares the experienced curtailment between distributed-PV only sites and distributed-PV coupled with battery sites for the first time. The study investigates and quantifies the energy loss due to curtailment within the South Australia region with over 40% distributed-PV penetration which has the highest uptake in the world. The results show that average curtailment loss was 1.5% for distributed-PV only sites and 0.2% for distributed-PV coupled with battery sites, however, some sites were heavily impacted losing up to 25% of generation. The reasons for the larger curtailment loss were identified as wiring and network connection faults and high voltage set-points at households' respective local substations. Other potential reason for the heavily impacted sites is being located towards the end of the low voltage feeder, however this couldn't be verified due to lack of spatial data. The large variation in curtailed generation across sites raises concerns for system owners and suggests further inquiry into the power-quality response mode design and regulations. The study also examines inverter conformance using real-world operational data for all three power quality response modes for the first time, and the results showed a low rate of conformance according to the Australian Standards and there were various discrepancies in the execution of these modes which raises concerns considering the increasing importance of distributed-PV and battery inverter fleet in supporting network operations and security. The results therefore warrant further investigation into the reasons behind these discrepancies and devising appropriate mechanisms to tighten inverter conformance checks. • Energy curtailment is calculated for D-PV only and D-PV coupled with BESS sites • Average loss due to curtailment is less than 2% of total D-PV generation • Curtailment is greater for D-PV only sites than D-PV coupled with BESS sites • Some sites lose up to 25% of generation due to curtailment • The large variation of curtailment losses across sites raises concerns • Inverters showed low conformance in power quality response mode standards [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
13640321
Volume :
186
Database :
Academic Search Index
Journal :
Renewable & Sustainable Energy Reviews
Publication Type :
Academic Journal
Accession number :
171847812
Full Text :
https://doi.org/10.1016/j.rser.2023.113696