Back to Search Start Over

No difference in mobile and fixed bearing partial knee arthroplasty in octogenarians: a clinical trial.

Authors :
D'Ambrosi, Riccardo
Valli, Federico
Nuara, Alessandro
Mariani, Ilaria
Di Feo, Fabrizio
Ursino, Nicola
Formica, Matteo
Mangiavini, Laura
Hantes, Michael
Migliorini, Filippo
Source :
European Journal of Orthopaedic Surgery & Traumatology. Oct2023, Vol. 33 Issue 7, p3081-3088. 8p.
Publication Year :
2023

Abstract

Background: A clinical trial comparing MB (mobile-bearing) versus FB (fixed-bearing) in medial partial knee arthroplasty (PKA) in octagenarians has been conducted. The focus of the present study was on PROMs, range of motion (ROM), implant positioning and implants survivorship. The hypothesis of the present study was that MB implants performed better than FB in PKA in octogenarians. Methods: The first group received FB PKA-PPK®; the second received MB PKA-Oxford. Patients were not randomly allocated. The following PROMs were administered at T0 (pre-operatively), T1 (1 year after surgery), and T2 (3 years after surgery): visual analogue scale (VAS), Knee Society Score (KSS) and Oxford Knee Score (OKS). Data regarding the implant survivorship and ROM were also collected. Furthermore, the following radiographic parameters were measured: Femoral component varus/valgus; Tibial component varus/valgus; Anteroposterior slope. Results: At T0, 28 patients were included in the FB and 33 in the MB group. The surgical time was shorter in the FB group (p < 0.001). No difference between FB and MB in ROM, VAS, KSS, and OKS at each follow-up (p > 0.05). No difference was found in implant positioning (p > 0.05). At last follow-up, FB group reported three failures caused by aseptic loosening. Four failures were observed in the MB cohort: two for bearing dislocation and two for aseptic loosening. The Kaplan–Meier Curve found no differences in implant survivorship. Conclusions: According to the main findings of the present clinical trial, MB implants performed similar to FB in PKA in octogenarians. The FB group demonstrated shorted surgical time. No difference was found in patient reported outcome measures, ROM, implant positioning, and survivorship. Level of evidence: Level II, prospective study. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
16338065
Volume :
33
Issue :
7
Database :
Academic Search Index
Journal :
European Journal of Orthopaedic Surgery & Traumatology
Publication Type :
Academic Journal
Accession number :
171993101
Full Text :
https://doi.org/10.1007/s00590-023-03537-7