External validation of a risk model predicting failure of salvage focal ablation for prostate cancer.

Authors :
Light, Alexander
Peters, Max
Reddy, Deepika
Kanthabalan, Abi
Otieno, Marjorie
Pavlou, Menelaos
Omar, Rumana
Adeleke, Sola
Giganti, Francesco
Brew‐Graves, Chris
Williams, Norman R.
Emara, Amr
Haroon, Athar
Latifoltojar, Arash
Sidhu, Harbir
Freeman, Alex
Orczyk, Clement
Nikapota, Ashok
Dudderidge, Tim
Hindley, Richard G.
Source :
BJU International. Nov2023, Vol. 132 Issue 5, p520-530. 11p.
Publication Year :
2023

Abstract

Objectives: To externally validate a published model predicting failure within 2 years after salvage focal ablation in men with localised radiorecurrent prostate cancer using a prospective, UK multicentre dataset. Patients and methods: Patients with biopsy‐confirmed ≤T3bN0M0 cancer after previous external beam radiotherapy or brachytherapy were included from the FOcal RECurrent Assessment and Salvage Treatment (FORECAST) trial (NCT01883128; 2014–2018; six centres), and from the high‐intensity focussed ultrasound (HIFU) Evaluation and Assessment of Treatment (HEAT) and International Cryotherapy Evaluation (ICE) UK‐based registries (2006–2022; nine centres). Eligible patients underwent either salvage focal HIFU or cryotherapy, with the choice based predominantly on anatomical factors. Per the original multivariable Cox regression model, the predicted outcome was a composite failure outcome. Model performance was assessed at 2 years post‐salvage with discrimination (concordance index [C‐index]), calibration (calibration curve and slope), and decision curve analysis. For the latter, two clinically‐reasonable risk threshold ranges of 0.14–0.52 and 0.26–0.36 were considered, corresponding to previously published pooled 2‐year recurrence‐free survival rates for salvage local treatments. Results: A total of 168 patients were included, of whom 84/168 (50%) experienced the primary outcome in all follow‐ups, and 72/168 (43%) within 2 years. The C‐index was 0.65 (95% confidence interval 0.58–0.71). On graphical inspection, there was close agreement between predicted and observed failure. The calibration slope was 1.01. In decision curve analysis, there was incremental net benefit vs a 'treat all' strategy at risk thresholds of ≥0.23. The net benefit was therefore higher across the majority of the 0.14–0.52 risk threshold range, and all of the 0.26–0.36 range. Conclusion: In external validation using prospective, multicentre data, this model demonstrated modest discrimination but good calibration and clinical utility for predicting failure of salvage focal ablation within 2 years. This model could be reasonably used to improve selection of appropriate treatment candidates for salvage focal ablation, and its use should be considered when discussing salvage options with patients. Further validation in larger, international cohorts with longer follow‐up is recommended. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
14644096
Volume :
132
Issue :
5
Database :
Academic Search Index
Journal :
BJU International
Publication Type :
Academic Journal
Accession number :
173152823
Full Text :
https://doi.org/10.1111/bju.16102