Back to Search Start Over

Self-powered biosensor using photoactive ternary nanocomposite: Testing the phospholipid content in rhodotorula glutinis oil.

Authors :
Wang, Weining
Zhang, Hairong
Wang, Donghua
Wang, Ning
Liu, Chang
Li, Ziyue
Wang, Liqi
Zhu, Xiuqing
Yu, Dianyu
Source :
Biosensors & Bioelectronics. Dec2023, Vol. 242, pN.PAG-N.PAG. 1p.
Publication Year :
2023

Abstract

In the field of oil refining, the presence of excessive residual phosphorus in crude oil can significantly impact its quality, thereby emphasizing the necessity for compact and convenient testing equipment. This study primarily focuses on developing of self-powered biosensor (SPB) using immobilizing Choline Oxidase with a photoactive ternary nanocomposite complex (CHOx-BiOI-rGO-Fe 3 O 4 NPs-ITO) as the anode and utilizing a Pt electrode as the cathode. The successful preparation of the ternary composite photoelectrode for the anode was confirmed through a range of characterization techniques, including X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), Transmission electron microscopy (TEM), Scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), N 2 absorption/desorption, Dynamic light scattering (DLS), and Ultraviolet–visible diffuse reflection spectrometer (UV–vis DRS). The electrochemical and photoelectrochemical properties were assessed using an electrochemical workstation, revealing a significant enhancement photoelectrical responsiveness attributed to the formation of heterojunction structures. The SPB exhibited a remarkable linear relationship between the instantaneous photocurrent and phosphatidylcholine (PC) concentration, with a regression equation of I (μA) = 39.62071C (mM) + 3.47271. The linear range covered a concentration range of 0.01–10 mM, and the detection limit (S/N = 3) was determined to be 0.008 mM. It demonstrated excellent reproducibility and storage stability, positioning it a promising alternative to High-performance liquid chromatography (HPLC) for accurate quantification of PC content in rhodotorula glutinis oil. The standard recovery PC content ranged from 98.48% to 103.53%, with a relative standard deviation (RSD) ranging from 1.4% to 2.4%. This research presents a convenient and precise detection device that has the potential to address the issue of lagging detection in the oil refining process. [Display omitted] [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09565663
Volume :
242
Database :
Academic Search Index
Journal :
Biosensors & Bioelectronics
Publication Type :
Academic Journal
Accession number :
173174752
Full Text :
https://doi.org/10.1016/j.bios.2023.115751