Back to Search Start Over

Uncertainty in magnetic resonance imaging-based prostate postimplant dosimetry: Results of a 10-person human observer study, and comparisons with automatic postimplant dosimetry.

Authors :
Sanders, Jeremiah W.
Tang, Chad
Kudchadker, Rajat J.
Venkatesan, Aradhana M.
Mok, Henry
Hanania, Alexander N.
Thames, Howard D.
Bruno, Teresa L.
Starks, Christine
Santiago, Edwin
Cunningham, Mandy
Frank, Steven J.
Source :
Brachytherapy. Nov2023, Vol. 22 Issue 6, p822-832. 11p.
Publication Year :
2023

Abstract

Uncertainties in postimplant quality assessment (QA) for low-dose-rate prostate brachytherapy (LDRPBT) are introduced at two steps: seed localization and contouring. We quantified how interobserver variability (IoV) introduced in both steps impacts dose-volume-histogram (DVH) parameters for MRI-based LDRPBT, and compared it with automatically derived DVH parameters. Twenty-five patients received MRI-based LDRPBT. Seven clinical observers contoured the prostate and four organs at risk, and 4 dosimetrists performed seed localization, on each MRI. Twenty-eight unique manual postimplant QAs were created for each patient from unique observer pairs. Reference QA and automatic QA were also performed for each patient. IoV of prostate, rectum, and external urinary sphincter (EUS) DVH parameters owing to seed localization and contouring was quantified with coefficients of variation. Automatically derived DVH parameters were compared with those of the reference plans. Coefficients of variation (CoVs) owing to contouring variability (CoV contours) were significantly higher than those due to seed localization variability (CoV seeds) (median CoV contours vs. median CoV seeds : prostate D90–15.12% vs. 0.65%, p < 0.001; prostate V100–5.36% vs. 0.37%, p < 0.001; rectum V100–79.23% vs. 8.69%, p < 0.001; EUS V200–107.74% vs. 21.18%, p < 0.001). CoV contours were lower when the contouring observers were restricted to the 3 radiation oncologists, but were still markedly higher than CoV seeds. Median differences in prostate D90, prostate V100, rectum V100, and EUS V200 between automatically computed and reference dosimetry parameters were 3.16%, 1.63%, −0.00 mL, and −0.00 mL, respectively. Seed localization introduces substantially less variability in postimplant QA than does contouring for MRI-based LDRPBT. While automatic seed localization may potentially help improve workflow efficiency, it has limited potential for improving the consistency and quality of postimplant dosimetry. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15384721
Volume :
22
Issue :
6
Database :
Academic Search Index
Journal :
Brachytherapy
Publication Type :
Academic Journal
Accession number :
173608749
Full Text :
https://doi.org/10.1016/j.brachy.2023.08.001