Back to Search
Start Over
Highly sensitive resistance spectroscopy technique for online monitoring of biofilm growth on metallic surfaces.
- Source :
-
Environmental Research . Jan2024:Part 2, Vol. 240, pN.PAG-N.PAG. 1p. - Publication Year :
- 2024
-
Abstract
- Online techniques for monitoring biofilm formation and evolution are limited, especially as regards its application in flowing water systems. This is chiefly due to the absence of efficient non-destructive and non-invasive sensing methods. In this study, a sensitive electrical resistance spectroscopy technique is developed to monitor non-invasively and in real time the growth of biofilms over metallic surfaces inside water flow systems. To this aim, Pseudomonas fluorescens strain is used for biofilm development lasting 72 h in a laboratory-scale test channel of orthogonal cross section. Biofilm development corresponds to a progressively increasing coverage of the metallic surface area up to full coverage and a progressively increasing thickness. Biofilm development is registered by continuous recording of electrical impedance signals (time series). Proper configuration and tuning of the electronics promote the resistive contribution to the signal whereas careful grounding diminishes electrical interferences and yields superb sensing sensitivity. An increase of relative electrical resistance of around 15% is noticed in 72 h flow experiments which is attributed to both an increase of metallic surface area coverage and an increase of biofilm thickness. An independent estimation of these quantities using imaging tools and microscopy analysis, indicates that full coverage of the metallic surface occurs after only 48 h of the flow experiment, whereas biofilm thickness increases gradually along the entire 72 h of the experiment. Cross-examination of electrical signals with biofilm characteristics (metallic surface coverage and biofilm thickness) reveals that, qualitatively speaking, electrical signals are rather more sensitive to metallic surface coverage than biofilm thickness. [Display omitted] • Custom-made resistance technique monitors biofilms on flow-wetted metallic surfaces. • Biofilms grow inside tailor-made millimeter-scale orthogonal flow channels. • High resolution electrical signals increase around 15% in 72 h of biofilm growth. • Electrical signals capture both increasing surface coverage and biofilm thickness. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00139351
- Volume :
- 240
- Database :
- Academic Search Index
- Journal :
- Environmental Research
- Publication Type :
- Academic Journal
- Accession number :
- 173700534
- Full Text :
- https://doi.org/10.1016/j.envres.2023.117401