Measurement of blood glycemic level from saliva for diabetic persons using microscopic image technique and analyzing through empirical Wavelet transform compared with invasive measurement of blood glucose using glucometer.
- Source :
-
AIP Conference Proceedings . 2023, Vol. 2587 Issue 1, p1-13. 13p. - Publication Year :
- 2023
-
Abstract
- The Blood Glycemic level(BG) is measured from saliva using Non-invasive technique through Empirical wavelet transform(EWT). A microscope image is a photograph or digital image that displays a magnified image of an object taken by a microscope. In this paper, a microscope image of saliva for 10 subjects(diabetic-5, non-diabetic-5) captured to measure the BG through Empirical Wavelet Transform. In this proposed work, it is observed that linear regression of non-invasive measurement has higher accuracy of 90% than invasive measurement with 86.8% accuracy and significance (p<0.01) through SPSS tool. Within the limitations of this study, BG measurement using saliva through EWT has a higher significance than an invasive technique. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 0094243X
- Volume :
- 2587
- Issue :
- 1
- Database :
- Academic Search Index
- Journal :
- AIP Conference Proceedings
- Publication Type :
- Conference
- Accession number :
- 173861351
- Full Text :
- https://doi.org/10.1063/5.0179587