STUDY ON THE SIMPLIFIED MODEL OF VERTICAL DOUBLE U-PIPE GROUND HEAT EXCHANGER.

Authors :
Xin WANG
Qiang FU
Changlong WANG
Source :
Thermal Science. 2023, Vol. 27 Issue 5B, p4035-4048. 14p.
Publication Year :
2023

Abstract

A simplified semi-analytical model of vertical double U-pipe ground heat exchanger was established. The validity of the established model is examined by contrasting the figured outcomes with experiment data, emulation results of 3-D numerical model and calculation results of infinite line-source model for different inlet boundary conditions and configurations. After one hour, the semi-analytical model's relative error is less than 0.32% under the boundary condition of given inlet fluid temperature. Under the boundary condition of given total heat input rate, the semi-analytical model's relative error after ten hours is less than 0.11%, while the infinite line-source model's relative error is less than 0.60%. The semi-analytical model is in good agreement with experiment and numerical model, and has higher calculation accuracy than infinite line-source model. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03549836
Volume :
27
Issue :
5B
Database :
Academic Search Index
Journal :
Thermal Science
Publication Type :
Academic Journal
Accession number :
173873242
Full Text :
https://doi.org/10.2298/TSCI220922048W