Back to Search Start Over

Robotic magnetic navigation‐guided catheter ablation establishes highly effective pulmonary vein isolation in patients with paroxysmal atrial fibrillation when compared to conventional ablation techniques.

Authors :
Noten, Anna M. E.
Romanov, Alexander
De Schouwer, Koen
Beloborodov, Vladimir
Bhagwandien, Rohit
Hoogendijk, Mark G.
Mikheenko, Igor
Wijchers, Sip
Yap, Sing‐Chien
Schwagten, Bruno
Szili‐Torok, Tamas
Source :
Journal of Cardiovascular Electrophysiology. Dec2023, Vol. 34 Issue 12, p2472-2483. 12p.
Publication Year :
2023

Abstract

Introduction: Pulmonary vein isolation (PVI) is a pivotal part of ablative therapy for atrial fibrillation (AF). Currently, there are multiple techniques available to realize PVI, including: manual‐guided cryoballoon (MAN‐CB), manual‐guided radiofrequency (MAN‐RF), and robotic magnetic navigation‐guided radiofrequency ablation (RMN‐RF). There is a lack of large prospective trials comparing contemporary RMN‐RF with the more conventional ablation techniques. This study prospectively compared three catheter ablation techniques as treatment of paroxysmal AF. Methods: This multicenter, prospective study included patients with paroxysmal AF who underwent their first ablation procedure. Procedural parameters (including procedural efficiency), complication rates, and freedom of AF during 12‐month follow‐up, were compared between three study groups which were defined by the utilized ablation technique. Results: A total of 221 patients were included in this study. Total procedure time was significantly shorter in MAN‐CB (78 ± 21 min) compared to MAN‐RF (115 ± 41 min; p <.001) and compared to RMN‐RF (129 ± 32 min; p <.001), whereas it was comparable between the two radiofrequency (RF) groups (p =.062). A 3% complication rate was observed, which was comparable between all groups. At 12‐month follow‐up, AF recurrence was observed in 40 patients (19%) and was significantly lower in the robotic group (MAN‐CB 19 [24%], MAN‐RF 16 [23%], RMN‐RF 5 [8%] AF recurrences, p =.045) (multivariate hazard ratio of RMN‐RF on AF recurrence 0.32, 95% confidence interval: 0.12–0.87, p =.026). Conclusion: RMN‐guided PVI results in high freedom of AF in patients with paroxysmal AF, when compared to cryoablation and manual RF ablation. Cryoablation remains the most time‐efficient ablation technique, whereas RMN nowadays has comparable efficiency with manual RF ablation. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10453873
Volume :
34
Issue :
12
Database :
Academic Search Index
Journal :
Journal of Cardiovascular Electrophysiology
Publication Type :
Academic Journal
Accession number :
174065163
Full Text :
https://doi.org/10.1111/jce.16081