Back to Search Start Over

Numerical investigation on the influence of geometrical parameters on the temperature distribution in marine hydrogen storage tanks during filling.

Authors :
Cui, Weiyi
Yuan, Yupeng
Wang, Hongyu
Tong, Liang
Source :
International Journal of Hydrogen Energy. Jan2024:Part A, Vol. 51, p61-71. 11p.
Publication Year :
2024

Abstract

This paper established a two-dimensional axisymmetric model with a marine high-pressure hydrogen storage tank as the research object. Using numerical simulation, the effects of different aspect ratios, inlet diameters, and inlet pipe lengths on the temperature rise of the hydrogen storage tank during the filling process were studied. As the L/D ratio of the hydrogen storage tank increases, the momentum of the hydrogen gas reaching the bottom of the tank gradually decreases, making it easier to form localized high-temperature regions. For a hydrogen storage tank with an L/D of 6.0, the difference between the maximum and average temperature at the end of filling was 155.85 K. In contrast, the temperature difference of the tank with an L/D of 3.6 was only 32.81 K. In addition, the inlet pipe delivers the hydrogen deep into the tank and reduces the obstructing effect of the existing hydrogen in the tank on the newly filled hydrogen. For smaller L/D hydrogen storage tanks, the inlet pipe may backfire and create a high-temperature zone at the shoulder of the tank. In contrast, for larger L/D hydrogen storage tanks, a suitable length of inlet pipe can deliver the hydrogen deep into the tank. This will enhance the gas flow inside the tank, facilitating heat exchange and avoiding the formation of localized high-temperature areas at the bottom of the tank. However, excessively long inlet pipes can also lead to high-temperature areas on the shoulders. At a specific charge mass flow rate, the lower the inlet diameter, the higher the hydrogen flow rate. The larger flow rate helped promote uniform hydrogen mixing in the tank and made it challenging to form localized high-temperature regions. • Effects of L/D ratio, inlet diameter and length on filling process are studied. • The inlet pipe lengths have different effects on cylinder with different L/D. • A suitable length of inlet tube can effectively reduce the hydrogen temperature. • Some recommendations are given to optimize the design of hydrogen storage tank. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03603199
Volume :
51
Database :
Academic Search Index
Journal :
International Journal of Hydrogen Energy
Publication Type :
Academic Journal
Accession number :
174339804
Full Text :
https://doi.org/10.1016/j.ijhydene.2023.10.300