Back to Search Start Over

Artemisia argyi essential oil as a green extraction solvent for in-syringe kapok fiber-supported liquid-phase microextraction and determination of triazole fungicide residues.

Authors :
Liu, Fanglin
Pang, Yongqiang
Liu, Dexiang
Cao, Qianwen
Rong, Ying
Liao, Xinglin
Jiang, Qiman
Xu, Peirong
Chen, Di
Xu, Xia
Source :
Microchemical Journal. Feb2024, Vol. 197, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

Schematic diagram of AAEO-based in-syringe KF-SLME-LC-MS/MS method for the determination of TFs. [Display omitted] • AAEO is used as a green solvent in in-syringe KF-SLME for hydrophobic compounds in aqueous samples. • AAEO-based in-syringe KF-SLME lowers LOQs by 5–50-fold for LC-MS/MS detection of TFs. • AAEO-based in-syringe KF-SLME provides rapid sample enrichment and purification in just ∼ 2 min. • The method with kapok fiber, AAEO, and ethanol shows excellent environmental friendliness. • It offers advantages in sensitivity, speed, applicability, environmental friendliness, and cost-effectiveness. In this study, Artemisia argyi essential oil (AAEO), extracted from the leaves of Artemisia argyi , was employed as a green extraction solvent for in-syringe kapok fiber-supported liquid-phase microextraction (KF-SLME) of hydrophobic compounds in aqueous samples. The wheat of natural kapok fiber as the support medium was 2 mg, and the optimum volume of the extraction solvent AAEO was 12.5 μL. The volume of green desorption solvent 75 % ethanol was 100 μL, which realized a highly environmentally friendly sample preparation method. By simply pulling and pushing the syringe plunger five times, the extraction process enabled rapid and convenient enrichment of analytes while removing most interferences. Coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS), the AAEO-based in-syringe SLME method was applied as a proof-of-concept study to determine triazole fungicides (TFs) residues in fruit juices, herbal oral liquids and herbal extract granules. Employing in-syringe KF-SLME prior to LC-MS/MS detection significantly reduced the limits of quantification (LOQs) by 5–50-fold. The integrated AAEO-based in-syringe KF-SLME-LC-MS/MS method demonstrated satisfactory linearity (R2 ≥ 0.995), accuracies (86.5 %–115.1 %), and precisions (1.2 %–12.7 %) using an isotope calibration method. Furthermore, three greenness assessment metrics uniformly highlighted its outstanding environmental friendliness. The proposed method offers competitive advantages in terms of its environmentally friendly approach, detection sensitivity, analysis cost, and operational convenience. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0026265X
Volume :
197
Database :
Academic Search Index
Journal :
Microchemical Journal
Publication Type :
Academic Journal
Accession number :
174842635
Full Text :
https://doi.org/10.1016/j.microc.2023.109868