Back to Search Start Over

Single-board low-noise fluxgate magnetometer.

Authors :
Dyer, T.
Griffin, P. F.
Riis, E.
Source :
Journal of Applied Physics. 1/21/2024, Vol. 135 Issue 3, p1-6. 6p.
Publication Year :
2024

Abstract

Low-noise fluxgate magnetometers are normally comprised of three separate devices: a power supply, the sensor head/electronics and an analog-to-digital converter (ADC). This paper presents a parallel rod fluxgate magnetometer in a single printed circuit board of size = 5 × 12 cm, weight = 45 g, and sensor head average power dissipation = 40 mW. The open-loop noise spectral density = 5 p T r m s / Hz @ 1 Hz , competitive with state-of-the-art devices. This is realized using a new amorphous wire core material and programmable mixed-signal electronics with low amplifier and ADC noise. We have compared the sensor performance to a low-noise observatory magnetometer and found sub-nT correlation when tracking the Y (East-West) component of the Earth's geomagnetic field. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00218979
Volume :
135
Issue :
3
Database :
Academic Search Index
Journal :
Journal of Applied Physics
Publication Type :
Academic Journal
Accession number :
174910819
Full Text :
https://doi.org/10.1063/5.0175418