Back to Search Start Over

Single primer/self-template-powered isothermal amplification for single-molecule quantification of multiple DNA glycosylases.

Authors :
Zhang, Yan
Liu, Ming-Hao
Wang, Xin-Yan
Zhu, Wencai
Li, Chen-Chen
Zhang, Chun-Yang
Source :
Sensors & Actuators B: Chemical. Apr2024, Vol. 404, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

DNA glycosylase assumes a pivotal role in the preservation of genome integrity by recognizing and excising damaged bases. Herein, we develop a single primer/self-template-powered cascade rolling circle amplification (RCA) and apurinic/apyrimidinic endonuclease (APE1)-mediated signal amplification for simultaneous detection of human alkyladenine DNA glycosylase (hAAG) and uracil DNA glycosylase (UDG). The uniqueness of this approach lies in the use of custom-designed hairpin probes to establish a prerequisite for RCA: the conformational change of hairpin probe to circular template, which effectively suppress undesired non-specific amplification. We design two hairpin probes featuring elongated stem structure and 3′-phosphate (3′-PO 4) modifications. The stems of hairpin probes are modified with glycosylase substrates and BER process can cleave hairpin probes, resulting in the generation of single-stranded DNAs (ssDNAs) with 3′-hydroxyl (3′-OH) ends. These ssDNAs can function as padlock probes to form circular template upon ligation by ligase. Ultimately, the self-template-initiated RCA and APE1-mediated signal amplification cascade occurs, generating a substantial number of free Cy3 and Cy5 fluorophores that can be simply visualized by single-molecule fluorescence detection. This method demonstrates excellent specificity and sensitivity, with a limit of detection (LOD) of 3.42 × 10-12 U/μL for hAAG and 2.41 × 10-12 U/μL for UDG. This method also can be used for screening of potential inhibitor and kinetic parameter measurement. Most importantly, this method enables accurate profiling of glycosylases expression levels in various cancer cell lines and detection of glycosylase activities at the single-cell level, offering a bright future in cancer detection, medical research, and precision medicine. • Simultaneous detection of multiple glycosylases at ultra-low concentrations. • Conformation-switchable hairpin probes and self-templated amplification reduce non-specific amplification. • One primer probe can simultaneously trigger two isothermal amplifications. • Accurate assessment of DNA glycosylase expression in different cancer cell lines. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09254005
Volume :
404
Database :
Academic Search Index
Journal :
Sensors & Actuators B: Chemical
Publication Type :
Academic Journal
Accession number :
175136385
Full Text :
https://doi.org/10.1016/j.snb.2024.135304