Determination of intraocular pressure and Schirmer tear test and the comparison between the applanation tonometer (Tono‐Pen AVIA®) and the rebound tonometer (TonoVet Plus®) in mini lionhead rabbits.

Authors :
Oliveira, Ismael V.
Oliveira, Lídia V. S. X.
Santos, Victória M. B.
Souza, João L. T.
Costa, Maria Lindomárcia. L.
Borges, Péricles F.
Campos, Danila B.
Talieri, Ivia C.
Source :
Veterinary Ophthalmology. Jan2024, Vol. 27 Issue 1, p53-60. 8p.
Publication Year :
2024

Abstract

Objective: To determine intraocular pressure (IOP) and tear production, as well as to compare the IOP obtained with the TonoVet Plus® (rebound) with the Tono‐Pen Avia® (applanation) tonometers. Animals: Twenty‐five Mini Lionhead rabbits (n = 50 eyes). Procedure: Tear production was measured at 6:00 a.m. and 6:00 p.m. by using the STT. The IOP reading was performed with the rebound tonometer, followed by the applanation tonometer, at 6:00 a.m., 9:00 a.m., 12:00 p.m., 3:00 p.m., and 6:00 p.m. Regression analysis, analysis of variance (anova) and Bland–Altman statistics were used. Results: Daily tear production was 10.25 ± 3.75 mm/min, with no differences among the moments evaluated. Average daily IOP was 17.7 ± 3.08 mmHg with the TonoVet Plus® and 11.5 ± 4.56 mmHg with the Tono‐Pen Avia®. IOP values were higher at the beginning and end of the day with both tonometers. Conclusion: The IOP values are higher with the TonoVet Plus® tonometer. The reference values of IOP and tear production obtained in this work may support the diagnosis, treatment, and monitoring of ocular disorders in pet Mini Lionhead rabbits. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
14635216
Volume :
27
Issue :
1
Database :
Academic Search Index
Journal :
Veterinary Ophthalmology
Publication Type :
Academic Journal
Accession number :
175140402
Full Text :
https://doi.org/10.1111/vop.13150