Back to Search Start Over

The image quality and feasibility of solitary delayed [68 Ga]Ga-PSMA-11 PET/CT using long field-of-view scanning in patients with prostate cancer.

Authors :
Yu, Xiaofeng
Xu, Lian
Huang, Gang
Liu, Jianjun
Chen, Ruohua
Chen, Yumei
Source :
EJNMMI Research. 2/6/2024, Vol. 14 Issue 1, p1-9. 9p.
Publication Year :
2024

Abstract

Background: Previous studies have demonstrated that delayed [68 Ga]Ga-PSMA PET/CT imaging improves lesion detection compared to early [68 Ga]Ga-PSMA PET/CT in patients with prostate cancer. However, the sole use of delayed [68 Ga]Ga-PSMA PET/CT has been limited due to the insufficient number of photons obtained with standard PET/CT scanners. The combination of early and delayed [68 Ga]Ga-PSMA standard PET/CT may be considered, and it is challenging to incorporate into a high-demand clinical setting. Long field-of-view (LFOV) PET/CT scanners have higher sensitivity compared to standard PET/CT. However, it remains unknown whether the image quality of solitary delayed [68 Ga]Ga-PSMA LFOV PET/CT imaging is adequate to satisfy clinical diagnostic requirements. Therefore, the purpose of this study was to evaluate the image quality of delayed [68 Ga]Ga-PSMA LFOV PET/CT and examine the feasibility of utilizing delayed [68 Ga]Ga-PSMA LFOV PET/CT imaging alone in patients with prostate cancer. Methods: The study sample consisted of 56 prostate cancer patients who underwent [68 Ga]Ga-PSMA-11 LFOV PET/CT scanning between December 2020 and July 2021. All patients were subjected to early LFOV PET/CT imaging at 1-h post-injection as well as delayed LFOV PET/CT imaging at 3-h post-injection using [68 Ga]Ga-PSMA-11. The image quality and diagnostic efficiency of solitary delayed [68 Ga]Ga-PSMA-11 LFOV PET/CT imaging was analyzed. Results: The results showed that delayed [68 Ga]Ga-PSMA-11 LFOV PET/CT yielded satisfactory image quality that fulfilled clinical diagnostic benchmarks. Compared to early imaging, delayed [68 Ga]Ga-PSMA-11 LFOV PET/CT demonstrated heightened lesion SUVmax values (11.0 [2.3–193.6] vs. 7.0 [2.0–124.3], P < 0.001) and superior tumor-to-background ratios (3.3 [0.5–62.2] vs. 1.7 [0.3–30.7], P < 0.001). Additionally, delayed [68 Ga]Ga-PSMA-11 LFOV PET/CT detected supplementary lesions in 14 patients (25%) compared to early imaging, resulting in modifications to disease staging and management plans. Conclusions: In summary, the findings indicate that the image quality of delayed [68 Ga]Ga-PSMA-11 LFOV PET/CT is satisfactory for meeting clinical diagnostic prerequisites. The use of solitary delayed [68 Ga]Ga-PSMA-11 LFOV PET/CT imaging in prostate cancer simplifies the examination protocol and improves patient compliance, compared to [68 Ga]Ga-PSMA-11 standard PET/CT which necessitates both early and delayed imaging. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
2191219X
Volume :
14
Issue :
1
Database :
Academic Search Index
Journal :
EJNMMI Research
Publication Type :
Academic Journal
Accession number :
175279741
Full Text :
https://doi.org/10.1186/s13550-024-01076-8