Fluorescence pressure sensors: Calibration of ruby, Sm2+: SrB4O7, and Sm3+: YAG to 55 GPa and 850 K.

Authors :
Wei, Yingzhan
Zhou, Qiang
Zhang, Caizi
Li, Liang
Li, Xinyang
Li, Fangfei
Source :
Journal of Applied Physics. 3/14/2024, Vol. 135 Issue 10, p1-15. 15p.
Publication Year :
2024

Abstract

In this work, a calibration of ruby, samarium-doped strontium tetraborate (Sm2+: SrB4O7), and samarium-doped yttrium aluminum garnet (Sm3+: YAG) using Raman and fluorescence spectra was conducted within the temperature range of 296–850 K and pressure range of 0–55 GPa. The obtained calibration can be applied independently for high-temperature or high-pressure conditions and described as the unit form of P = (A′/B′) × [(λ/λT)B′ − 1] with A′ = A (296 K) + A1 × (T − 296) + A2 × (T − 296)2, B′ = B(296 K) + B1 × (T – 296), and λT = λT (296 K) + ΔλT, where the specific parameters are provided in the main text. It was observed that for the λ1 line (5D0 → 7F0 transition, about 685.2 nm under ambient conditions, also known as the 0-0 line) of Sm2+: SrB4O7, the neglect of the temperature effect on the pressure coefficient may lead to an underestimation of pressure above 35–40 GPa, with a maximum deviation of approximately 2.5 GPa within the range of 55 GPa and 850 K. For Sm3+: YAG, it may introduce significant errors under the whole high temperature and high pressure range if the effect of temperature is ignored, that is, about 3.9 GPa for Y1 line (4G5/2 → 6H7/2 transition, about 617.8 nm under ambient conditions) and 4.6 GPa for Y2 line (4G5/2 → 6H7/2 transition, about 616.0 nm under ambient conditions) at 850 K. Comparing the three fluorescence pressure sensors, the ruby has the strongest signal intensity and highest temperature sensitivity, and the Sm2+: SrB4O7 and the Sm3+: YAG possess lower temperature sensibility, wider used temperature range, and better spectral quality under high temperature and high pressure (HTHP), especially Sm2+: SrB4O7, which has a sharp high-intensity single peak λ1, perhaps the most promising sensor for high P–T experiments. Therefore, in view of the potential deflections of fluorescence peaks of each pressure sensor under HTHP, we recommend utilizing the HTHP-corrected relationships for pressure calibration. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00218979
Volume :
135
Issue :
10
Database :
Academic Search Index
Journal :
Journal of Applied Physics
Publication Type :
Academic Journal
Accession number :
176070502
Full Text :
https://doi.org/10.1063/5.0178597