Stability, homogeneity and measurement uncertainty estimation of PVP-I solutions for the application on oro and nasopharynx against SARS-CoV-2.

Authors :
Moniruzzaman, Md.
Razu, Mamudul Hasan
Rahman, Sad Al Rezwan
Kundu, Nayan Kumer
Kamal, Sabiha
Khan, Mala
Source :
Scientific Reports. 3/27/2024, Vol. 14 Issue 1, p1-11. 11p.
Publication Year :
2024

Abstract

Aqueous solution containing different concentration (0.5, 0.6 and 1.0%) (w/v) of Polyvinyl pyrrolodon-Iodine (PVP-I) complex, a well-known antiseptic; is prepared and the stability and homogeneity of these solution is assessed as per the ICH Guidelines and International Harmonized Protocol respectively. The solutions were found to be sufficiently homogeneous and stable for a year at 25 °C (60%RH). Measurement uncertainty of the prepared PVP-I solutions were estimated by identifying possible sources of uncertainty using Ishikawa diagram and preparing uncertainty budget based on scope of calibration laboratory. The stable and homogenized PVP-I solution is to be used in a clinical trial for the application on oro and nasopharynx against novel SARS-CoV-2 Virus. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20452322
Volume :
14
Issue :
1
Database :
Academic Search Index
Journal :
Scientific Reports
Publication Type :
Academic Journal
Accession number :
176300284
Full Text :
https://doi.org/10.1038/s41598-024-52346-3