Back to Search Start Over

Demographic, Clinical, Management, and Outcome Characteristics of 8,004 Young Children With Type 1 Diabetes.

Authors :
Sandy, Jessica L.
Tittel, Sascha R.
Rompicherla, Saketh
Karges, Beate
James, Steven
Rioles, Nicole
Zimmerman, Anthony G.
Fröhlich-Reiterer, Elke
Maahs, David M.
Lanzinger, Stefanie
Craig, Maria E.
Ebekozien, Osagie
Craig, Maria
Colman, Peter
Glastras, Sarah
Jones, Tim
Johnson, Stephanie
Sinnott, Richard
Zimmerman, Anthony
Anderson, Kym
Source :
Diabetes Care. Apr2024, Vol. 47 Issue 4, p660-667. 8p.
Publication Year :
2024

Abstract

OBJECTIVE: To compare demographic, clinical, and therapeutic characteristics of children with type 1 diabetes age <6 years across three international registries: Diabetes Prospective Follow-Up Registry (DPV; Europe), T1D Exchange Quality Improvement Network (T1DX-QI; U.S.), and Australasian Diabetes Data Network (ADDN; Australasia). RESEARCH DESIGN AND METHODS: An analysis was conducted comparing 2019–2021 prospective registry data from 8,004 children. RESULTS: Mean ± SD ages at diabetes diagnosis were 3.2 ± 1.4 (DPV and ADDN) and 3.7 ± 1.8 years (T1DX-QI). Mean ± SD diabetes durations were 1.4 ± 1.3 (DPV), 1.4 ± 1.6 (T1DX-QI), and 1.5 ± 1.3 years (ADDN). BMI z scores were in the overweight range in 36.2% (DPV), 41.8% (T1DX-QI), and 50.0% (ADDN) of participants. Mean ± SD HbA1c varied among registries: DPV 7.3 ± 0.9% (56 ± 10 mmol/mol), T1DX-QI 8.0 ± 1.4% (64 ± 16 mmol/mol), and ADDN 7.7 ± 1.2% (61 ± 13 mmol/mol). Overall, 37.5% of children achieved the target HbA1c of <7.0% (53 mmol/mol): 43.6% in DPV, 25.5% in T1DX-QI, and 27.5% in ADDN. Use of diabetes technologies such as insulin pump (DPV 86.6%, T1DX 46.6%, and ADDN 39.2%) and continuous glucose monitoring (CGM; DPV 85.1%, T1DX-QI 57.6%, and ADDN 70.5%) varied among registries. Use of hybrid closed-loop (HCL) systems was uncommon (from 0.5% [ADDN] to 6.9% [DPV]). CONCLUSIONS: Across three major registries, more than half of children age <6 years did not achieve the target HbA1c of <7.0% (53 mmol/mol). CGM was used by most participants, whereas insulin pump use varied across registries, and HCL system use was rare. The differences seen in glycemia and use of diabetes technologies among registries require further investigation to determine potential contributing factors and areas to target to improve the care of this vulnerable group. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01495992
Volume :
47
Issue :
4
Database :
Academic Search Index
Journal :
Diabetes Care
Publication Type :
Academic Journal
Accession number :
176364752
Full Text :
https://doi.org/10.2337/dc23-1317