Back to Search Start Over

Efficacy and safety of 3D reconstruction and basket multi‐electrode renal denervation (RDN) for refractory hypertensive patients with chronic kidney disease.

Authors :
Cai, Han
Fang, Zhoufei
Wu, Xiangshu
Zhou, Wei
Lin, Jinxiu
Peng, Feng
Su, Jinzi
Source :
Journal of Clinical Hypertension. Apr2024, Vol. 26 Issue 4, p338-348. 11p.
Publication Year :
2024

Abstract

Renal Artery Sympathetic Denervation (RDN) can lower blood pressure. Different ablation catheters (single electrode, multi‐electrode) have different scopes of ablation (renal artery main stem and branches). Few studies have compared the advantages and disadvantages of different ablation catheters and different procedures in terms of antihypertensive efficacy. To compare the efficacy and safety of 3D reconstruction radiofrequency ablation (3DRA) and basket multi‐electrode radiofrequency ablation (BMRA) in Renal Artery Sympathetic Denervation. Fifty‐three patients with Refractory hypertension (RHT) were divided into BMRA, (n = 28) and 3DRA(n = 25). BMRA group used a stereobasket multi‐electrode ablation catheter with a controlled ablation temperature of 60°C and an ablation time of 120 s per site. 3DRA group used a NavStar pressure‐monitored perfusion monopolar ablation catheter with a controlled ablation temperature of 40°C, an ablation time of 40 s per site, and an ablation energy of 12 W. Baseline and RDN parameters and complications were compared in both groups. Home and 24 h ambulatory blood pressure, type of anti‐hypertensive medication taken, and serum creatinine were followed up at 1, 3, 6, 12, and 24 months after the RDN. There were no differences in baseline characteristics between the two groups. (23.14 ± 2.00)months of follow‐up in the BMRA group resulted in a total of (25.86 ± 8.61) loci ablation. (19.28 ± 7.40)months of follow‐up in the 3DRA group resulted in a total of (21.04 ± 6.47)loci ablation. Home SBP was significantly lower in both groups at 1 month after RDN treatment compared to baseline(H‐SBP/mmHg: BMRA 149.9 ± 10.59 vs. baseline 168.36 ± 12.76; 3DRA 152.6 ± 14.91 vs. 164.89 ± 12.96, both p <.05). The proportion of people with 24 h ambulatory SBP attainment was significantly higher in both groups and was maintained for 24 months. At each follow‐up time point, there were no differences in home and 24‐h flow SBP, DBP, or Scr between the two groups. There were two cases of severe renal artery complications from implanted vascular stents and one case of femoral artery pseudoaneurysm in the 3DRA group. At follow‐up, 1 (1.9%) patient in the 3DRA group died of unexplained death and 1 (1.9%) patient developed heart failure, and 1 (1.9%) patient in the BMRA group died of unexplained death. Basket multi‐electrode radiofrequency ablation and 3D reconstruction radiofrequency ablation of the renal artery applied to RDN have comparable efficacy in reducing systolic blood pressure. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15246175
Volume :
26
Issue :
4
Database :
Academic Search Index
Journal :
Journal of Clinical Hypertension
Publication Type :
Academic Journal
Accession number :
176537456
Full Text :
https://doi.org/10.1111/jch.14781