Back to Search Start Over

An rolling circle amplification-assisted CRISPR/Cas12a-based biosensor for protein detection.

Authors :
Wang, Wen
Geng, Lu
Zhang, Yiyang
Shen, Weili
Bi, Meng
Gong, Tingting
Liu, Cong
Hu, Zhiyong
Guo, Changjiang
Sun, Tieqiang
Source :
Microchemical Journal. May2024, Vol. 200, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

Principle of An rolling circle amplification-assisted CRISPR/Cas12a for HbA1c detection: [Display omitted] • The clever combination of magnetic beads, antibody and rolled loop amplification improves sensitivity. • The PAM sequence on the double-stranded DNA specifically recognized by CRISPR Cas12a is split into two parts. • High sensitivity, high specificity, short detection time, simple operation. • The detection limit in buffer is 0.129 pg/mL. The detection limit in serum is 0.317 pg/mL. Glycated hemoglobin (HbA1c) has been extensively studied as a pivotal marker for monitoring and diagnosing diabetes. In this study, we introduce a highly sensitive and rapid enzyme-catalyzed rolling circle amplification (RCA)-assisted nicked-PAM CRISPR/Cas12a assay (termed "RANPC"). The RANPC system initially recognizes and captures the target using immunomagnetic beads and antibodies, forming a sandwich structure. The antibodies, upon ligating the primers, trigger the RCA reaction, resulting in the generation of single-stranded DNA with numerous repetitive sequences. The product strand of RCA then initiates the trans -cutting activity of nicked-PAM CRISPR/Cas12a, ultimately reporting the target concentration through fluorescent signaling. This study combines dual antibody capture, signal amplification through RCA, and signal output by Cas12a, resulting in high sensitivity, high specificity, and high signal-to-noise ratio. Moreover, the strategic incorporation of an incomplete PAM design in the CRISPR/Cas12a system substantially reduces background interference and enhances assay specificity relative to previous conventional Cas12a detection methods. RANPC possesses advantages such as ultra-sensitivity (with the lowest detection limit up to 0.129 pg/mL and a linear range of 12.8 pg/mL to 1 µg/mL), high specificity, rapid reaction time (approximately 50 min), and straightforward operation. Under optimized experimental conditions, we successfully detected HbA1c in eight real-world blood samples, and the results were in good agreement with the theoretical values. This suggests that this method holds promise as a new approach for the analysis of HbA1c levels in the clinical setting. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0026265X
Volume :
200
Database :
Academic Search Index
Journal :
Microchemical Journal
Publication Type :
Academic Journal
Accession number :
176648210
Full Text :
https://doi.org/10.1016/j.microc.2024.110370