Back to Search
Start Over
Radiophotoluminescence response of LiF:Mg,Ti pellets irradiated with clinical proton beams in the 70–200 MeV energy range.
- Source :
-
Radiation Measurements . Jun2024, Vol. 174, pN.PAG-N.PAG. 1p. - Publication Year :
- 2024
-
Abstract
- Lithium fluoride doped with Mg and Ti (LiF:Mg,Ti) has been used for several decades as thermoluminescent dosimeter material, but recently also its radiophotoluminescence has been investigated for applications in dosimetry. In this work, LiF:Mg,Ti pellets (TLD-100) were irradiated in a water phantom at CNAO (Pavia, Italy) with therapeutic proton beams at five energies from 70 to 200 MeV in the dose range from 2 to 20 Gy. After irradiation, their visible radiophotoluminescence spectra were measured in controlled conditions and the spectrally-integrated red emission response of radiation-induced color centers has been investigated. The radiophotoluminescence signal, excited by a 445 nm continuous wave laser, was integrated within a 50 nm-wide band around the emission peak of the F 2 color centers, located around 670 nm in LiF. The spectrally-integrated signal of the samples irradiated at the energy of 147.7 MeV exhibited a linear dependence with dose. Moreover, this radiophotoluminescence response appears independent from Linear Energy Transfer in the range from 0.8 to 1.6 keV/μm in all the samples irradiated at the dose of 5 Gy. Such independence was found up to 10.3 keV/μm in samples irradiated within two spread out Bragg peaks made of 36 energy components in the entire investigated proton energy range. The radiophotoluminescence response of the TLD-100 pellets was compared to that of nominally-pure LiF crystals irradiated in the same conditions, which show a similar behavior. The results are encouraging for the exploitation of TLD-100 pellets as passive solid-state radiophotoluminescent dosimeters for proton therapy. • Experimental study of RPL response of TLD-100 irradiated with clinical proton beams. • RPL of F 2 color centers in TLD-100 pellets linear vs dose in 2–20 Gy at E p = 148 MeV. • RPL of F 2 color centers in TLD-100 pellets independent from proton beam energy. • Same RPL behavior measured also in undoped LiF crystals identically irradiated. • Laser-excited visible RPL of TLD-100 promising for dosimetry in protontherapy. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 13504487
- Volume :
- 174
- Database :
- Academic Search Index
- Journal :
- Radiation Measurements
- Publication Type :
- Academic Journal
- Accession number :
- 177197850
- Full Text :
- https://doi.org/10.1016/j.radmeas.2024.107153