Back to Search Start Over

Evaluation of a Digital Amsler Grid (PocDoc) for Macular Disease Screening: A Comparative Analysis with the Conventional Method.

Authors :
Boon, Joewee
Rojas-Carabali, William
Asad, Yusra
Lim, Jonathan Tzien Yih
Rajagopalan, Rajesh
Agrawal, Rupesh
Source :
Ophthalmology & Therapy. May2024, Vol. 13 Issue 5, p1289-1301. 13p.
Publication Year :
2024

Abstract

Introduction: Macular diseases are major contributors to visual impairment and blindness worldwide. This study introduces PocDoc, a digital version of the conventional Amsler grid, aimed at enhancing the screening and monitoring of macular diseases. We conducted a comprehensive evaluation to compare the effectiveness of PocDoc against the conventional method. Methods: Our comparative analysis involved two distinct phases. Initially, we assessed the capability of both PocDoc and the conventional method in detecting central visual field abnormalities. This phase included a cohort of 72 healthy and 155 eyes affected by various conditions such as age-related macular degeneration (AMD), uveitis, polypoidal choroidal vasculopathy (PCV), and macular telangiectasia. We primarily focused on the area of compromise and observed the correlation between the results obtained from both methods, measuring their concordance using a correlation coefficient. In the second phase, we evaluated the accuracy of both methods in diagnosing AMD. This involved a group of 127 eyes, including 70 healthy and 57 AMD-affected eyes. We determined the sensitivity, specificity, and overall accuracy of each method in diagnosing AMD. Results: In the initial phase, both PocDoc and the conventional Amsler grid demonstrated a high correlation in detecting central visual field defects across various macular diseases (correlation coefficient > 0.9). In the second phase, focused on AMD diagnosis, PocDoc showed a sensitivity of 50%, specificity of 100%, and an overall accuracy of 78%. Comparatively, the conventional method exhibited a sensitivity of 49%, specificity of 100%, and accuracy of 77%. Conclusion: PocDoc's digital Amsler grid exhibits comparable effectiveness to the conventional method in both detecting visual field abnormalities across a range of macular diseases and specifically in the diagnosis of AMD. The high correlation in results, combined with the digital advantages of PocDoc, such as ease of use and potential for telemedicine applications, suggests its viability as a valuable tool in the screening and monitoring of macular diseases. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
21938245
Volume :
13
Issue :
5
Database :
Academic Search Index
Journal :
Ophthalmology & Therapy
Publication Type :
Academic Journal
Accession number :
177775161
Full Text :