Back to Search Start Over

Enhancement of pH imaging of light addressable potentiometric sensor by colloidal spherical lens array.

Authors :
Tan, Jie
Liu, Shibin
Luo, Jiezhang
Chen, Yinghao
Zhao, Wenbo
Li, Huijuan
Li, Guifang
Li, Xueliang
Source :
Microchemical Journal. Aug2024, Vol. 203, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

[Display omitted] • Light addressable potentiometric sensor modified by colloidal spherical lens array was proposed. • Polystyrene colloidal spherical lens array was monolayer, well-ordered and low-cost. • This LAPS device shows acceptable pH sensing. • This LAPS device widens the modulation frequency of the maximum photoresponse to 40 kHz. • This LAPS device shows high-spatiotemporal pH imaging capability. Visualizing the distribution of pH in a solution is an important basis for monitoring reaction processes and metabolic changes in micro-biochemical species. Light addressable potentiometric sensor (LAPS), as a simple structure, flexible imaging, low-cost and label-free electrochemical sensor, has been widely used to pH imaging. However, its spatiotemporal resolution is greatly affected by the frequency of modulation light, thus limiting its imaging performance. In this study, LAPS device modified by well-ordered and low-cost polystyrene (PS) colloidal monolayer as spherical lens array is proposed to obtain higher available modulation frequency of the maximum photoresponse. The morphology, optical properties and the electric field distribution of PS colloidal spherical lens array were tested and analyzed. pH sensing, imaging of uniform pH solution, the spatiotemporal pH imaging and dynamic imaging of enzymatic reactions of LAPS modified by PS colloidal spherical lens array were tested and evaluated. The experimental results show that LAPS modified by PS colloidal spherical lens array not only has acceptable pH sensing, but also widens the modulation frequency of the maximum photoresponse to 40 kHz. LAPS modified by colloidal spherical lens array modulated at the frequency of 40 kHz shows acceptable sensitivity and linearity, good reproducibility and stability, high SNR and high-spatiotemporal pH imaging capability. This work can be suitable for high-spatiotemporal monitoring of the changes in electrolyte environmental pH caused by the reaction and metabolism of the biochemical species. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0026265X
Volume :
203
Database :
Academic Search Index
Journal :
Microchemical Journal
Publication Type :
Academic Journal
Accession number :
177908037
Full Text :
https://doi.org/10.1016/j.microc.2024.110863